Skip to main content
Siemens 3VA1180-6EF36-0DC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1180-6EF36-0DC0 SENTRON MCCB, 80 A, 220 kA at 240

MPN3VA1180-6EF36-0DC0

Siemens SENTRON 3VA1180-6EF36-0DC0, molded case circuit breaker, 3-pole, 80 A continuous, TM240 thermal-magnetic release, 220 kA breaking capacity at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1180-6EF36-0DC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1180-6EF36-0DC0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C80 A
Current at 45 °C80 A
Current at 50 °C80 A
Current at 55 °C76.8 A
Current at 60 °C75.2 A
Current at 65 °C73.6 A
Current at 70 °C72 A
Switching capacity classH
Breaking capacity at 240 V220 kA
Breaking capacity at 415 V154 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 690 V17 kA
3VA1180-6EF36-0DC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
3VA1180-6EF36-0DC0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1180-6EF36-0DC0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA1180-6EF36-0DC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1180-6EF36-0DC0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

What this MCCB delivers

The Siemens SENTRON 3VA1180-6EF36-0DC0 is a 3-pole molded case circuit breaker rated for 80 A continuous current at 40 °C through 50 °C, with a TM240 thermal-magnetic overcurrent release. Its interrupting capacity reaches 220 kA at 240 V, 154 kA at 415 V, and 121 kA at 440 V — enough to handle high-fault utility feeds or transformer secondaries without cascading upstream. The breaker carries an undervoltage release (UVR) as standard and two HQ auxiliary switches for status feedback.

Above that it derates: 76.8 A at 55 °C, 75.2 A at 60 °C, 73.6 A at 65 °C, and 72 A at 70 °C. If the panel ambient runs at 60 °C, plan for a 75 A load ceiling. The dimensions — 130 mm high, 76.2 mm wide, 70 mm deep — fit standard SENTRON 3VA panel cutouts; the IP40 front rating means it's suited for enclosed distribution boards, not washdown zones.

Frequently asked questions

How do I get current pricing and availability for 3VA1180-6EF36-0DC0?

Submit an RFQ through this listing. Pricing and stock are confirmed at quote time; the part is sourced to order through independent distribution channels.

What are the key ratings for this MCCB?

Rated 80 A continuous (flat to 50 °C), 3-pole, TM240 thermal-magnetic release, with interrupting capacities of 220 kA at 240 V, 154 kA at 415 V, 121 kA at 440 V, and 17 kA at 690 V. Rated insulation voltage is 800 V.

MPN
3VA1180-6EF36-0DC0