Siemens 3VA1180-6GE42-0AA0 SENTRON MCCB, 80 A, 4-Pole, 220 k

MPN3VA1180-6GE42-0AA0
Active

Siemens SENTRON 3VA1180-6GE42-0AA0, molded case circuit breaker, 4-pole, 80 A, TM220 overcurrent release, breaking capacity 220 kA at 240 V, 154 kA at 415 V, 121 kA at 440 V, IP40 front.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1180-6GE42-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON

Ratings

3VA1180-6GE42-0AA0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C80 A
Current at 45 °C80 A
Current at 50 °C80 A
Current at 55 °C78 A
Current at 60 °C77 A
Current at 65 °C75 A
Current at 70 °C74 A
Switching capacity classH
Breaking capacity at 240 V220 kA
Breaking capacity at 415 V154 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V17 kA
Breaking capacity at 690 V17 kA
Power loss, max.19.2 W

Protection & Trip Unit

3VA1180-6GE42-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM220
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA1180-6GE42-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1180-6GE42-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA1180-6GE42-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1180-6GE42-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width101.6 mm
Depth70 mm
Height (in)5.12 in
Width (in)4 in
Depth (in)2.76 in

Product details

MCCB for line protection — 80 A, 4-pole, TM220 release

The Siemens 3VA1180-6GE42-0AA0 is a SENTRON molded case circuit breaker (MCCB) rated 80 A continuous, with a 4-pole configuration and a TM220 thermal-magnetic overcurrent release. Designed for line protection, it carries a breaking capacity of 220 kA at 240 V AC, 154 kA at 415 V, and 121 kA at 440 V — figures that govern its ability to safely interrupt fault currents without upstream cascade failure per IEC 60947-2. The TM220 release provides fixed thermal and magnetic trip settings, suitable for feeder and distribution applications where adjustable trip units are not required.

Thermal derating and panel integration

At 40 °C the breaker carries its full 80 A rating; derating begins at 55 °C (78 A) and reaches 74 A at 70 °C, per the evidence. The 70 mm depth and 101.6 mm width fit standard DIN-rail or panel-mount enclosures — verify gland-plate clearance for the 130 mm height when installing in a shallow enclosure. Front IP40 protection suits indoor panel environments; no washdown rating is claimed.

Frequently asked questions

Where can I buy 3VA1180-6GE42-0AA0 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is the breaking capacity of 3VA1180-6GE42-0AA0 at different voltages?

Breaking capacity is 220 kA at 240 V, 154 kA at 415 V, 121 kA at 440 V, and 17 kA at 500 V and 690 V.

MPN
3VA1180-6GE42-0AA0