Skip to main content
Siemens 3VA1196-3ED12-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1196-3ED12-0AA0 SENTRON MCCB, 1P, 16 A, 52.5 kA

MPN3VA1196-3ED12-0AA0
Active

Siemens SENTRON 3VA1, molded case circuit breaker, 1-pole, 16 A (40 °C), TM210 release, 52.5 kA at 240 V AC, 70 mm depth, 25.4 mm width, 130 mm height.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1196-3ED12-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA1196-3ED12-0AA0 — Ratings
ParameterValue
Number of poles1
Rated operational voltage Ue (AC)415 V
Rated insulation voltage Ui500 V
Current at 40 °C16 A
Current at 45 °C16 A
Current at 50 °C16 A
Current at 55 °C16 A
Current at 60 °C15 A
Current at 65 °C15 A
Current at 70 °C15 A
Switching capacity classN
Breaking capacity at 240 V52.5 kA
Breaking capacity at 415 V7.5 kA
Power loss, max.3.53 W
3VA1196-3ED12-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1196-3ED12-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1196-3ED12-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0
3VA1196-3ED12-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1196-3ED12-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width25.4 mm
Depth70 mm
Height (in)5.12 in
Width (in)1 in
Depth (in)2.76 in

Product details

Siemens 3VA1196-3ED12-0AA0 — 1-Pole 16 A SENTRON MCCB, TM210 Release

The Siemens 3VA1196-3ED12-0AA0 is a SENTRON molded case circuit breaker (MCCB) in a 1-pole form factor, rated 16 A at 40 °C with a TM210 thermal-magnetic overcurrent release. Its interrupting capacity hits 52.5 kA at 240 V AC and 7.5 kA at 415 V AC, making it a solid choice for line protection in distribution panels where high fault current is a concern.

Rated current holds at 16 A from 40 °C through 55 °C, then derates to 15 A at 60 °C through 70 °C. That flat thermal curve means you don't lose headroom until the ambient inside the enclosure pushes past 55 °C — useful when the MCCB shares a crowded DIN rail with other heat sources. Breaking capacity of 52.5 kA at 240 V AC covers most North American 120/240 V split-phase service entrance requirements. At 415 V AC (common in European 400 V three-phase systems), it still clears 7.5 kA — adequate for downstream sub-distribution but not for high-fault main breakers. The 125 V DC rating (operating voltage) opens the door for DC control circuits or battery-backed loads. Physical footprint: 25.4 mm wide (1 inch), 130 mm tall, 70 mm deep. That 1-pole width matches standard DIN-rail modular breaker spacing — it clips onto the rail and occupies one module position.

The 3VA1196-3ED12-0AA0 carries RoHS, REACH, and CE marking. The device manual is available under Service & Support on Siemens' site.

MPN
3VA1196-3ED12-0AA0