Skip to main content
Siemens 3VA1196-3ED22-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1196-3ED22-0AA0 SENTRON MCCB, 2-Pole, 16A, 75.6kA

MPN3VA1196-3ED22-0AA0
Active

Siemens SENTRON molded case circuit breaker, 2-pole, 16 A rated current, 75.6 kA breaking capacity at 240 V AC, TM210 thermal-magnetic trip, line protection design, IP40 front, active production.

$80.01Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1196-3ED22-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA1196-3ED22-0AA0 — Ratings
ParameterValue
Number of poles2
Rated operational voltage Ue (AC)415 V
Rated insulation voltage Ui500 V
Current at 40 °C16 A
Current at 45 °C16 A
Current at 50 °C16 A
Current at 55 °C16 A
Current at 60 °C15 A
Current at 65 °C15 A
Current at 70 °C15 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Power loss, max.7.06 W
3VA1196-3ED22-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1196-3ED22-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1196-3ED22-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0
3VA1196-3ED22-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1196-3ED22-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width50.8 mm
Depth70 mm
Height (in)5.12 in
Width (in)2 in
Depth (in)2.76 in

Product details

The Siemens SENTRON 3VA1196-3ED22-0AA0 is a 2-pole molded case circuit breaker rated for 16 A continuous duty across a 40 °C to 55 °C ambient range, with a thermal-magnetic TM210 overcurrent release. Breaking capacity hits 75.6 kA at 240 V AC and 52.5 kA at 415 V AC, so it handles high-fault utility feeds without needing an upstream current-limiting fuse. At 70 °C ambient the rating drops to 15 A — still a solid 15 A, but if your panel runs hot near a transformer or drive, size the load accordingly. Insulation voltage is 500 V, operating voltage 415 V AC or 250 V DC, so it covers most industrial control panels and lighting distribution boards.

The case measures 50.8 mm wide, 130 mm tall, 70 mm deep — a 2-inch wide footprint that fits standard panel-mount cutouts for 2-pole MCCBs.

Frequently asked questions

What is the breaking capacity of 3VA1196-3ED22-0AA0?

75.6 kA at 240 V AC and 52.5 kA at 415 V AC — high enough for most industrial service entrances and distribution panels without needing a current-limiting fuse upstream.

What is the closest functional second-source for 3VA1196-3ED22-0AA0?

The 3VA1110-5ED32-0AA0 is a similar 2-pole SENTRON MCCB but with a different trip unit and current rating. It shares the same frame dimensions but the trip curve and ampacity differ — verify load coordination before substituting.

How do I get current pricing and availability for 3VA1196-3ED22-0AA0?

Submit an RFQ through this page. We source it against your order; availability and price are confirmed at quote time.

MPN
3VA1196-3ED22-0AA0