Skip to main content
Siemens 3VA1196-3EF32-0CA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1196-3EF32-0CA0 SENTRON MCCB, 3-Pole, 16 A, 75.6

MPN3VA1196-3EF32-0CA0

Siemens SENTRON 3VA1196-3EF32-0CA0, 3-pole molded case circuit breaker, 16 A rated current, 75.6 kA breaking capacity at 240 V AC, undervoltage release, line protection design.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1196-3EF32-0CA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA11963EF320AA0
3VA1196-3EF32-0CA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C16 A
Current at 45 °C16 A
Current at 50 °C16 A
Current at 55 °C16 A
Current at 60 °C15 A
Current at 65 °C15 A
Current at 70 °C15 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 500 V11.9 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.13.1 W
3VA1196-3EF32-0CA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1196-3EF32-0CA0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1196-3EF32-0CA0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1196-3EF32-0CA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1196-3EF32-0CA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

The Siemens 3VA1196-3EF32-0CA0 is a 3-pole SENTRON molded case circuit breaker (MCCB) rated for line protection, with a continuous current of 16 A across ambient temperatures from 40 °C to 55 °C, derating to 15 A at 60 °C through 70 °C. Its interrupting capacity is 75.6 kA at 240 V AC, 52.5 kA at 415 V, 32 kA at 440 V, and 11.9 kA at both 500 V and 690 V — numbers that define the available fault current it can safely clear at the point of installation.

Built-in undervoltage release for coordinated protection

The UVR is factory-integrated, so there's no separate module to mount or wire inside the panel; it's a single order-code solution for applications requiring undervoltage protection per NEC 430.74 or IEC 60947-2.

At 70 mm deep, 76.2 mm wide, and 130 mm tall, this MCCB fits standard SENTRON 3VA mounting footprints and drops into existing panel layouts without re-drilling or bus-bar rework. The 3-pole design with 16 A continuous rating and integrated UVR makes it a direct replacement for earlier 3VA1 frame breakers in retrofit applications, provided the existing bus system supports the 76.2 mm pole spacing.

Thermal-magnetic trip and power dissipation

Maximum power loss is 13.1 W per pole, which matters for enclosure heat-load calculations when multiple breakers are ganged in a sealed panel.

Frequently asked questions

Where can I buy the 3VA1196-3EF32-0CA0 and get a price?

This part is sourced to order against an RFQ through our independent distribution network. Submit a request for quote (RFQ) and we'll confirm availability and current pricing.

What are the key ratings of the 3VA1196-3EF32-0CA0?

It's a 3-pole MCCB rated 16 A continuous (derated to 15 A above 60 °C), with interrupting capacity of 75.6 kA at 240 V, 52.5 kA at 415 V, 32 kA at 440 V, and 11.9 kA at 500/690 V. Rated insulation voltage is 800 V.

Does this MCCB include an undervoltage release?

Yes, it has a factory-integrated undervoltage release (UVR) as the auxiliary release, which trips the breaker when supply voltage drops below the threshold.

What are the physical dimensions of the 3VA1196-3EF32-0CA0?

Depth is 70 mm, width is 76.2 mm, and height is 130 mm.

MPN
3VA1196-3EF32-0CA0