Skip to main content
Siemens 3VA1196-3EF32-0KA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1196-3EF32-0KA0 SENTRON MCCB, 16A 3-Pole 75.6kA

MPN3VA1196-3EF32-0KA0

Siemens SENTRON 3VA1196-3EF32-0KA0, Molded case circuit breaker, 3-pole, 16 A (40 °C), 75.6 kA at 240 V, shunt trip (STL), TM240 overcurrent release, line protection.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1196-3EF32-0KA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA11963EF320AA0
3VA1196-3EF32-0KA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C16 A
Current at 45 °C16 A
Current at 50 °C16 A
Current at 55 °C16 A
Current at 60 °C15 A
Current at 65 °C15 A
Current at 70 °C15 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 500 V11.9 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.10.6 W
3VA1196-3EF32-0KA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1196-3EF32-0KA0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1196-3EF32-0KA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1196-3EF32-0KA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1196-3EF32-0KA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

The Siemens SENTRON 3VA1196-3EF32-0KA0 is a 3-pole molded case circuit breaker (MCCB) rated 16 A continuous at 40 °C ambient — no derating needed until you hit 60 °C, where it drops to 15 A. Breaking capacity hits 75.6 kA at 240 V, 52.5 kA at 415 V, and still holds 11.9 kA up at 690 V, so it handles high-fault industrial panels without cascading upstream.

At 76.2 mm wide, 130 mm tall, and 70 mm deep, this MCCB occupies a standard 3-pole MCCB footprint — it mounts on a DIN rail or direct panel with the SENTRON mounting accessories.

Frequently asked questions

Where can I buy 3VA1196-3EF32-0KA0 and get a price?

This MCCB is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm number.

What is the breaking capacity of this MCCB at 240 V?

75.6 kA at 240 V, derating to 52.5 kA at 415 V and 11.9 kA at 690 V. That's a high-interrupting rating suitable for main or sub-feed breakers in industrial panels.

Does this breaker include a shunt trip?

Yes, the design of the auxiliary release is a shunt trip (STL), allowing remote tripping via a control voltage. The undervoltage release is not included.

What compliance documentation is available for this part?

As a Siemens SENTRON MCCB, it carries the standard IEC/UL certifications for the series. Specific RoHS, REACH, and UL file numbers are part of the manufacturer's declaration package available on request.

MPN
3VA1196-3EF32-0KA0