Skip to main content
Siemens 3VA1196-4EF32-0AC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1196-4EF32-0AC0 SENTRON MCCB, 16 A, 121 kA at 240

MPN3VA1196-4EF32-0AC0

Siemens SENTRON 3VA1196-4EF32-0AC0, molded case circuit breaker, 3-pole, 16 A, TM240 release, 121 kA at 240 V, 70 mm depth.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1196-4EF32-0AC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1196-4EF32-0AC0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C16 A
Current at 45 °C16 A
Current at 50 °C16 A
Current at 55 °C15.36 A
Current at 60 °C15.04 A
Current at 65 °C14.72 A
Current at 70 °C14.4 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V52.5 kA
Breaking capacity at 690 V11.9 kA
3VA1196-4EF32-0AC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
3VA1196-4EF32-0AC0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1196-4EF32-0AC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA1196-4EF32-0AC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1196-4EF32-0AC0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

Its breaking capacity hits 121 kA at 240 V, 75.6 kA at 415 V, 52.5 kA at 440 V, and 11.9 kA at 690 V — so it handles high-fault scenarios across common industrial voltages without cascading upstream.

The 16 A rating holds flat from 40 °C to 50 °C; above that it derates linearly to 14.4 A at 70 °C. The 76.2 mm width (3-inch pitch) fits standard MCCB panel cutouts and bus-bar spacing.

Frequently asked questions

What is the breaking capacity of 3VA1196-4EF32-0AC0 at 415 V?

75.6 kA at 415 V. At 240 V it's 121 kA, at 440 V it's 52.5 kA, and at 690 V it's 11.9 kA.

Where can I buy 3VA1196-4EF32-0AC0?

This part is sourced to order through independent distribution. Submit an RFQ; availability and current pricing are confirmed at quote time.

What is the rated current of 3VA1196-4EF32-0AC0?

The rated continuous current Iu is 16 A, holding flat from 40 °C to 50 °C and derating to 14.4 A at 70 °C.

Does 3VA1196-4EF32-0AC0 include auxiliary contacts?

Yes, it comes with 2 auxiliary switches (HQ type) for status feedback. No undervoltage release or ground-fault monitoring is fitted.

MPN
3VA1196-4EF32-0AC0