Skip to main content
Siemens 3VA1196-4EF36-0BC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1196-4EF36-0BC0 SENTRON MCCB, 16A, 3-Pole, 121kA

MPN3VA1196-4EF36-0BC0

Siemens SENTRON 3VA1196-4EF36-0BC0, molded case circuit breaker, 3-pole, 16 A rated at 40 °C, line protection design, with undervoltage release and 2 auxiliary switches HQ.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1196-4EF36-0BC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA11964EF360AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12

Ratings

3VA1196-4EF36-0BC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C16 A
Current at 45 °C16 A
Current at 50 °C16 A
Current at 55 °C16 A
Current at 60 °C15 A
Current at 65 °C15 A
Current at 70 °C15 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V52.5 kA
Breaking capacity at 500 V11.9 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.13.1 W

Protection & Trip Unit

3VA1196-4EF36-0BC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA1196-4EF36-0BC0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal on both sides
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1196-4EF36-0BC0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA1196-4EF36-0BC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1196-4EF36-0BC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

Siemens 3VA1196-4EF36-0BC0 — SENTRON MCCB for Line Protection

The Siemens 3VA1196-4EF36-0BC0 is a SENTRON molded case circuit breaker (MCCB) designed for line protection in distribution panels. It carries a continuous current rating of 16 A across ambient temperatures from 40 °C to 55 °C, derating to 15 A at 60 °C through 70 °C — so in a warm enclosure you lose 1 A of headroom above 55 °C. This is a 3-pole unit with an interrupting capacity of 121 kA at 240 V AC, 75.6 kA at 415 V, 52.5 kA at 440 V, and 11.9 kA at both 500 V and 690 V. At 415 V — common for industrial motor feeders — the 75.6 kA SCCR gives substantial fault-clearing headroom for most low-voltage switchgear lineups. Rated insulation voltage is 800 V, and maximum power loss is 13.1 W. The breaker ships with an undervoltage release (UVR) and two auxiliary switches (HQ design) pre-installed — that saves a panel-builder a separate wiring step for remote status or shunt-trip monitoring.

Panel Fit & Integration Notes

Dimensions are 130 mm height, 76.2 mm width, 70 mm depth — a standard SENTRON 3VA frame that fits Siemens distribution panels and most third-party enclosures with DIN-rail or screw-mount provisions. The 70 mm depth means it clears shallow backpanels where a deeper MCCB would conflict with wiring ducts or rear-mounted busbars. Operating temperature range is -25 °C to 70 °C; storage range is -40 °C to 80 °C. No communication function or ground-fault monitoring is built in — this is a straight thermal-magnetic line-protection breaker, not a power-monitoring device.

MPN
3VA1196-4EF36-0BC0