Skip to main content
Siemens 3VA1196-4EF36-0CA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1196-4EF36-0CA0 SENTRON MCCB, 16A 3-Pole, 121kA a

MPN3VA1196-4EF36-0CA0

Siemens SENTRON 3VA1196-4EF36-0CA0, molded case circuit breaker, 3-pole, 16 A rated at 40 °C, 121 kA breaking capacity at 240 V AC, with undervoltage release (UVR).

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1196-4EF36-0CA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA11964EF360AA0
3VA1196-4EF36-0CA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C16 A
Current at 45 °C16 A
Current at 50 °C16 A
Current at 55 °C16 A
Current at 60 °C15 A
Current at 65 °C15 A
Current at 70 °C15 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V52.5 kA
Breaking capacity at 500 V11.9 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.13.1 W
3VA1196-4EF36-0CA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1196-4EF36-0CA0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal on both sides
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1196-4EF36-0CA0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1196-4EF36-0CA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1196-4EF36-0CA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

SENTRON 3VA1 MCCB with undervoltage release

Its 121 kA breaking capacity at 240 V AC and 75.6 kA at 415 V AC give it the interrupting capability for high-fault service-entrance or sub-distribution applications where fault currents are substantial.

Breaking capacity and thermal rating

Rated uninterrupted current holds at 16 A from 40 °C up to 55 °C, then derates to 15 A at 60 °C through 70 °C — so in a warm enclosure near the top of the ambient range, plan for the 15 A limit. The 121 kA at 240 V AC is the highest short-circuit rating on this frame; at 415 V AC it still delivers 75.6 kA, and at 690 V AC it holds 11.9 kA. That spread covers most industrial supply voltages without needing a larger frame just for interrupting capacity.

The 3VA1196-4EF36-0CA0 measures 130 mm high, 76.2 mm wide, and 70 mm deep — a compact 3-pole footprint that fits standard DIN-rail or screw-mounted panel layouts common in Siemens SENTRON distribution boards. The 70 mm depth leaves clearance behind the gland plate for wiring and the UVR coil connections.

Frequently asked questions

What is the breaking capacity of 3VA1196-4EF36-0CA0 at 415 V?

At 415 V AC the breaking capacity is 75.6 kA, which covers most industrial low-voltage distribution fault levels.

What does the undervoltage release (UVR) do on this MCCB?

The UVR trips the breaker when the control voltage falls below a set threshold, used in safety circuits to disconnect loads on loss of control power.

Where can I buy 3VA1196-4EF36-0CA0?

This part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time.

MPN