Skip to main content
Siemens 3VA1196-5ED36-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1196-5ED36-0AA0 SENTRON MCCB, 16 A, 3-Pole, 187 k

MPN3VA1196-5ED36-0AA0
Active

Siemens SENTRON 3VA1 molded case circuit breaker, 3VA1196-5ED36-0AA0, 16 A rated current, 3-pole, TM210 thermal-magnetic release, 187 kA breaking capacity at 240 V AC, IP40 front protection.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1196-5ED36-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection

Ratings

3VA1196-5ED36-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C16 A
Current at 45 °C16 A
Current at 50 °C16 A
Current at 55 °C16 A
Current at 60 °C15 A
Current at 65 °C15 A
Current at 70 °C15 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 500 V17 kA
Breaking capacity at 690 V17 kA
Power loss, max.10.6 W

Protection & Trip Unit

3VA1196-5ED36-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout

Construction & Connection

3VA1196-5ED36-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal on both sides
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1196-5ED36-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA1196-5ED36-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1196-5ED36-0AA0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

Breaking capacity and selectivity

The 3VA1196-5ED36-0AA0: This MCCB delivers 187 kA at 240 V AC, 121 kA at 415 V, 75.6 kA at 440 V, and 17 kA at both 500 V and 690 V. At 240 V the 187 kA figure is the highest in the 3VA1 16 A class — it lets you install this breaker downstream of a large transformer without needing a current-limiting upstream device. At 690 V the 17 kA rating still covers most industrial motor branch circuits. The 800 V rated insulation voltage (Ui) confirms the internal clearance supports 690 V line-to-line switching.

Thermal derating and enclosure fit

Rated current holds at 16 A from 40 °C through 55 °C ambient; it derates to 15 A at 60 °C and 65 °C, and stays at 15 A up to the 70 °C operating maximum. The 10.6 W maximum power loss means you can group several breakers in a standard IP40 enclosure without forced ventilation — just keep the 70 mm depth and 76.2 mm width per pole spacing in mind for the DIN-rail layout. Front IP40 protection is standard; the breaker has no trip indicator, undervoltage release, or communication module, so it's a straight thermal-magnetic device for basic line protection.

Current-production status (lifecycle stage 'current') means this order code is the active manufacturing variant — no end-of-life notice, no successor to track. For a critical-spare holding or a BOM freeze, this is the part you spec today and can reorder against an RFQ through independent distribution. Compliance documentation (RoHS, REACH, UL, IEC) is available from the manufacturer's support portal under the 3VA series device manual.

Frequently asked questions

What is the breaking capacity of this MCCB at 240 V?

187 kA at 240 V AC, which is the highest rating in the 3VA1 16 A class and allows installation downstream of large transformers without upstream current-limiting devices.

Where can I buy 3VA1196-5ED36-0AA0?

Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

What does the TM210 release designation mean?

TM210 means a fixed thermal pickup at 16 A with magnetic short-circuit protection set at 10× In, so the instantaneous trip fires at 160 A — a standard coordination point for motor branch circuits or feeder protection.

Does this breaker include a trip indicator or undervoltage release?

No — the 3VA1196-5ED36-0AA0 has no trip indicator, no undervoltage release, and no communication function. It is a straight thermal-magnetic device for basic line protection.

MPN
3VA1196-5ED36-0AA0