Siemens 3VA1196-5EF32-0AA0-ZD00 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1196-5EF32-0AA0-ZD00 3VA1 IEC Frame 160 MCCB, 55k

MPN3VA1196-5EF32-0AA0-ZD00

Siemens 3VA1 IEC frame 160 MCCB, breaking capacity class M, Icu=55kA @ 415V, 3-pole, line protection TM240 ATAM, In=16A, overload Ir=11A...16A, short-circuit Ii=10...20 x In, nut keeper kit for DC Power OEM in China.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Product details

What the ratings mean for your panel

The 3VA1196-5EF32-0AA0-ZD00 is a 3-pole IEC molded-case circuit breaker on the 3VA1 frame, rated for a breaking capacity Icu of 55 kA at 415 V AC — class M in Siemens' 3VA hierarchy. That 55 kA figure governs the maximum fault current the breaker can safely interrupt at the panelboard; if your upstream transformer or bus can deliver more than that, you need a higher-class frame (class H or class S) or a current-limiting upstream device. The thermal-magnetic trip unit is a TM240 ATAM, with overload protection adjustable from 11 A to 16 A (Ir) and short-circuit protection set at 10 to 20 times In (Ii). That means for a 16 A In, the magnetic pickup ranges from 160 A to 320 A — sized for motor-starting inrush or transformer magnetizing current without nuisance tripping, but verify coordination with downstream branch breakers.

Panel integration notes

Mounts on a standard DIN rail or panel-mount via the 3VA1 frame's integral lugs. The TM240 ATAM trip unit is field-replaceable without removing the breaker from the bus. Terminals accept copper or aluminum conductors up to the frame's rated cross-section; torque values are marked on the breaker face. The nut keeper kit is a mechanical retention feature for the terminal screws — useful in high-vibration environments like DC power OEM skids.

Frequently asked questions

How do I get current pricing and availability for 3VA1196-5EF32-0AA0-ZD00?

This part is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current pricing and availability — confirmed at quote time.

What is the breaking capacity of this MCCB?

The Icu is 55 kA at 415 V AC, class M on the 3VA1 frame — suitable for high-fault panels where the available fault current is up to that level.

What are the overload and short-circuit protection settings?

Overload protection Ir is adjustable from 11 A to 16 A. Short-circuit protection Ii is adjustable from 10 to 20 times In (160 A to 320 A for a 16 A In).