Siemens 3VA1196-5EF32-0AB0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1196-5EF32-0AB0 SENTRON MCCB, 16A, 3-Pole, 187kA

MPN3VA1196-5EF32-0AB0

Siemens SENTRON 3VA1196-5EF32-0AB0, molded case circuit breaker, 3-pole, 16 A rated at 40 °C, TM240 overcurrent release, 187 kA breaking capacity at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1196-5EF32-0AB0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA11965EF320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA11
3VA1196-5EF32-0AB0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C16 A
Current at 45 °C16 A
Current at 50 °C16 A
Current at 55 °C16 A
Current at 60 °C15 A
Current at 65 °C15 A
Current at 70 °C15 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 500 V17 kA
Breaking capacity at 690 V17 kA
Power loss, max.10.6 W
3VA1196-5EF32-0AB0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1196-5EF32-0AB0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1196-5EF32-0AB0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA1196-5EF32-0AB0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1196-5EF32-0AB0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

The 3VA1196-5EF32-0AB0: Rated at 16 A continuously at ambient temperatures from 40 °C through 55 °C, derating to 15 A at 60 °C through 70 °C. This thermal curve means the breaker holds its full 16 A rating across typical panel internal temperatures; only above 55 °C does a 1 A derate apply, which is relevant if the MCCB sits near transformers or in a tightly packed enclosure. Breaking capacity is 187 kA at 240 V, 121 kA at 415 V, 75.6 kA at 440 V, and 17 kA at 500 V and 690 V. The TM240 release is thermal-magnetic, meaning it provides both overload (thermal) and short-circuit (magnetic) protection without electronic adjustment. Power loss is 10.6 W maximum — a figure to factor into enclosure thermal calculations when multiple breakers are ganged in a panel.

Auxiliary switch and variant note

This order code includes 2 auxiliary switches (HP design) factory-fitted. The supplied basic switch variant is 3VA11965EF320AA0, which is the core MCCB without auxiliaries. If you need a different auxiliary configuration, the base variant is the reference point for field-installable accessories.

Frequently asked questions

Where can I buy 3VA1196-5EF32-0AB0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the breaking capacity of 3VA1196-5EF32-0AB0 at 240 V?

The breaking capacity is 187 kA at 240 V, 121 kA at 415 V, 75.6 kA at 440 V, and 17 kA at both 500 V and 690 V.

What is the rated current of 3VA1196-5EF32-0AB0?

It is rated 16 A continuously at ambient temperatures from 40 °C through 55 °C, derating to 15 A at 60 °C through 70 °C.

MPN
3VA1196-5EF32-0AB0