Siemens 3VA1196-5EF32-0HH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1196-5EF32-0HH0 SENTRON MCCB, 16 A, 187 kA at 240

MPN3VA1196-5EF32-0HH0

Siemens SENTRON 3VA1196-5EF32-0HH0, 3-pole molded case circuit breaker, 16 A rated continuous current, interrupting 187 kA at 240 V, line protection version with TM240 overcurrent release.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1196-5EF32-0HH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA1196-5EF32-0HH0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C16 A
Current at 45 °C16 A
Current at 50 °C16 A
Current at 55 °C15.36 A
Current at 60 °C15.04 A
Current at 65 °C14.72 A
Current at 70 °C14.4 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 690 V17 kA
3VA1196-5EF32-0HH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
3VA1196-5EF32-0HH0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1196-5EF32-0HH0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA1196-5EF32-0HH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1196-5EF32-0HH0 — Mechanical
ParameterValue
Height130 mm
Width76.2 mm
Depth70 mm

Product details

Its interrupting capacity hits 187 kA at 240 V, 121 kA at 415 V, 75.6 kA at 440 V, and 17 kA at 690 V — those numbers tell you it's built for high-fault panels where a standard MCB would weld shut.

Panel fit and derating reality

At 70 mm deep, 76.2 mm wide, and 130 mm tall, this MCCB fits a standard 3-pole footprint on a DIN rail or panel-mount base. The front face is IP40 — fine inside a closed cabinet, not for washdown. The derating table matters: it holds 16 A flat from 40 °C to 50 °C, then drops to 15.36 A at 55 °C, 15.04 A at 60 °C, 14.72 A at 65 °C, and 14.4 A at 70 °C.

Frequently asked questions

What interrupting capacity does this MCCB have at 415 V?

It interrupts 121 kA at 415 V. That's sufficient for most industrial distribution panels with high fault current availability downstream of a large transformer.

Where can I buy 3VA1196-5EF32-0HH0 and how is it quoted?

We source this part through independent distribution channels. Submit an RFQ for current pricing and availability — we confirm both at quote time.

MPN