Skip to main content
Siemens 3VA1196-6ED42-0AA0 — Molded Case Circuit Breakers (MCCB)

SENTRON 3VA1196-6ED42-0AA0 MCCB, 4-pole, 16 A, TM210, 220 kA

MPN3VA1196-6ED42-0AA0
Active

SENTRON 3VA1196-6ED42-0AA0, molded case circuit breaker, 4-pole, 16 A (Iu), TM210 thermal-magnetic release, breaking capacity 220 kA at 240 V, 154 kA at 415 V, 121 kA at 440 V, 17 kA at 500/690 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1196-6ED42-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA1196-6ED42-0AA0 — Ratings
ParameterValue
Number of poles4
Current at 45 °C16 A
Current at 50 °C16 A
Current at 55 °C16 A
Current at 60 °C15 A
Current at 65 °C15 A
Current at 70 °C15 A
Switching capacity classH
Breaking capacity at 240 V220 kA
Breaking capacity at 415 V154 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V17 kA
Breaking capacity at 690 V17 kA
Power loss, max.10.6 W
3VA1196-6ED42-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
3VA1196-6ED42-0AA0 — Construction & Connection
ParameterValue
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1196-6ED42-0AA0 — Accessories & Functions
ParameterValue
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1196-6ED42-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1196-6ED42-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width101.6 mm
Depth70 mm
Height (in)5.12 in
Width (in)4 in
Depth (in)2.76 in

Product details

Its interrupting capacity reaches 220 kA at 240 V, 154 kA at 415 V, and 121 kA at 440 V, dropping to 17 kA at 500 V and 690 V. The TM210 release is adjustable; the maximum response current setting is 320 A.

Thermal derating and operating envelope

The breaker holds its full 16 A rating from 45 °C through 55 °C. At 60 °C it derates to 15 A, and it maintains 15 A through 70 °C. Maximum power loss is 10.6 W.

Front-panel protection is IP40. The breaker accepts a motor drive option. Dimensions: 130 mm height, 101.6 mm width, 70 mm depth. The 4-pole form factor fits standard MCCB panel cutouts and busbar systems for line protection duty.

Frequently asked questions

Where can I buy 3VA1196-6ED42-0AA0 and how do I get a price?

This part is available to order through our independent distribution channel. Submit an RFQ for current pricing and lead time confirmation.

What is the breaking capacity of 3VA1196-6ED42-0AA0 at 415 V?

154 kA at 415 V. It also carries ratings of 220 kA at 240 V, 121 kA at 440 V, and 17 kA at 500 V and 690 V.

MPN
3VA1196-6ED42-0AA0