Skip to main content
Siemens 3VA1196-6EF32-0BC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1196-6EF32-0BC0 SENTRON MCCB, 16 A, 220 kA at 240

MPN3VA1196-6EF32-0BC0

Siemens SENTRON 3VA1196-6EF32-0BC0, molded case circuit breaker, 3-pole, 16 A rated current, 220 kA breaking capacity at 240 V AC, line protection design, undervoltage release, 70 mm depth.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1196-6EF32-0BC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA11966EF320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12

Ratings

3VA1196-6EF32-0BC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C16 A
Current at 45 °C16 A
Current at 50 °C16 A
Current at 55 °C16 A
Current at 60 °C15 A
Current at 65 °C15 A
Current at 70 °C15 A
Switching capacity classH
Breaking capacity at 240 V220 kA
Breaking capacity at 415 V154 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V17 kA
Breaking capacity at 690 V17 kA
Power loss, max.13.1 W

Protection & Trip Unit

3VA1196-6EF32-0BC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA1196-6EF32-0BC0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1196-6EF32-0BC0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA1196-6EF32-0BC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1196-6EF32-0BC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

What this MCCB delivers for a panel build

The Siemens SENTRON 3VA1196-6EF32-0BC0 is a 3-pole molded case circuit breaker (MCCB) rated 16 A continuous, with a breaking capacity of 220 kA at 240 V AC and 154 kA at 415 V AC — high enough for most industrial main or feeder applications where fault current is substantial. Rated current holds at 16 A from 40 °C up to 55 °C, then derates to 15 A at 60 °C and above — useful to know if the breaker sits in a warm enclosure or near other heat sources. It carries an undervoltage release (UVR) as standard, so it can trip on loss of control voltage — a common requirement for emergency-stop circuits or safety-related disconnects. Dimensions are 130 mm height, 76.2 mm width, 70 mm depth — fits standard SENTRON panel cutouts and busbar systems.

Frequently asked questions

Does 3VA1196-6EF32-0BC0 include an undervoltage release?

Yes, it comes with an undervoltage release (UVR) as standard — trips the breaker on loss of control voltage.

MPN
3VA1196-6EF32-0BC0