The Siemens SENTRON 3VA1196-6EF32-0BC0 is a 3-pole molded case circuit breaker (MCCB) rated 16 A continuous, with a breaking capacity of 220 kA at 240 V AC and 154 kA at 415 V AC — high enough for most industrial main or feeder applications where fault current is substantial. Rated current holds at 16 A from 40 °C up to 55 °C, then derates to 15 A at 60 °C and above — useful to know if the breaker sits in a warm enclosure or near other heat sources.

Siemens 3VA1196-6EF32-0BC0 SENTRON MCCB, 16 A, 220 kA at 240
MPN3VA1196-6EF32-0BC0
Siemens SENTRON 3VA1196-6EF32-0BC0, molded case circuit breaker, 3-pole, 16 A rated current, 220 kA breaking capacity at 240 V AC, line protection design, undervoltage release, 70 mm depth.
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026
Specifications
| Parameter | Value |
|---|---|
| Product designation | Molded case circuit breaker |
| Brand / range | SENTRON |
| Basic switch (supplied) ref. | 3VA11966EF320AA0 |
| Integrated auxiliary / alarm switch ref. | 3VA9988-0AA12 |
| Parameter | Value |
|---|---|
| Number of poles | 3 |
| Rated operational voltage Ue (AC) | 690 V |
| Rated insulation voltage Ui | 800 V |
| Current at 40 °C | 16 A |
| Current at 45 °C | 16 A |
| Current at 50 °C | 16 A |
| Current at 55 °C | 16 A |
| Current at 60 °C | 15 A |
| Current at 65 °C | 15 A |
| Current at 70 °C | 15 A |
| Switching capacity class | H |
| Breaking capacity at 240 V | 220 kA |
| Breaking capacity at 415 V | 154 kA |
| Breaking capacity at 440 V | 121 kA |
| Breaking capacity at 500 V | 17 kA |
| Breaking capacity at 690 V | 17 kA |
| Power loss, max. | 13.1 W |
| Parameter | Value |
|---|---|
| Overcurrent release (trip unit) type | TM240 |
| Overcurrent protection function | LI |
| Ground-fault monitoring | Without |
| Grounding protection function | No |
| Parameter | Value |
|---|---|
| Main circuit connection type | nut keeper kit on both ends |
| Main circuit connector arrangement | Front terminal |
| Protection class (IP), front | IP40 |
| Parameter | Value |
|---|---|
| Undervoltage release | Yes |
| Voltage trigger | No |
| Trip indicator | No |
| Communication function | No |
| Measurement function | No |
| Motor drive option | Yes |
| Auxiliary CO contacts | 2 |
| Parameter | Value |
|---|---|
| Operating temperature, max. | 70 °C |
| Operating temperature, min. | -25 °C |
| Storage temperature, max. | 80 °C |
| Storage temperature, min. | -40 °C |
| Parameter | Value |
|---|---|
| Mechanical service life (operating cycles), typ. | 20 000 |
| Height | 130 mm |
| Width | 76.2 mm |
| Depth | 70 mm |
| Height (in) | 5.12 in |
| Width (in) | 3 in |
| Depth (in) | 2.76 in |
Product details
Frequently asked questions
Does 3VA1196-6EF32-0BC0 include an undervoltage release?
Yes, it comes with an undervoltage release (UVR) as standard — trips the breaker on loss of control voltage.
MPN
3VA1196-6EF32-0BC0