Skip to main content
Siemens 3VA1196-6EF32-0JH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1196-6EF32-0JH0 SENTRON MCCB, 16 A, 3-Pole, 220 k

MPN3VA1196-6EF32-0JH0

Siemens SENTRON 3VA1196-6EF32-0JH0, molded case circuit breaker, 3-pole, 16 A rated, 220 kA breaking cap at 240 V, line protection design.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1196-6EF32-0JH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA11966EF320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA1196-6EF32-0JH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C16 A
Current at 45 °C16 A
Current at 50 °C16 A
Current at 55 °C16 A
Current at 60 °C15 A
Current at 65 °C15 A
Current at 70 °C15 A
Switching capacity classH
Breaking capacity at 240 V220 kA
Breaking capacity at 415 V154 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V17 kA
Breaking capacity at 690 V17 kA
Power loss, max.10.6 W
3VA1196-6EF32-0JH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1196-6EF32-0JH0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1196-6EF32-0JH0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA1196-6EF32-0JH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1196-6EF32-0JH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

What ships in the carton — and what the ratings mean for your panel

The 3VA1196-6EF32-0JH0: Inside the box you get the breaker with a shunt trip (STL) auxiliary release, plus two auxiliary switches and one trip alarm switch (HQ) pre-installed. That means the kit is complete for signaling the breaker state back to a PLC or annunciator — no separate accessory order needed for basic status feedback. The breaker also includes a voltage trip indicator, so a quick visual check tells you it tripped on a fault versus being manually opened.

Thermal derating — the 16 A rating holds up to 55 °C

The continuous current rating is 16 A from 40 °C through 55 °C ambient. At 60 °C it derates to 15 A, and holds at 15 A through 70 °C. That's a tight thermal curve — you lose only 1 A over a 30 °C rise above 55 °C, which gives you headroom in a warm enclosure. The maximum power loss is 10.6 W, so factor that into your panel heat budget if you're stacking several breakers side by side.

DIN-rail footprint and panel fit

The breaker measures 76.2 mm wide, 130 mm tall, and 70 mm deep. That 70 mm depth is the dimension you care about for gland-plate clearance or shallow backpanels — it's the same depth class as most SENTRON 3VA frame sizes, so it drops into existing cutouts without re-drilling. The 3-pole width of 76.2 mm (3 inches) matches the standard 3-module DIN-rail footprint for this frame family.

Frequently asked questions

What is the breaking capacity of 3VA1196-6EF32-0JH0 at different voltages?

At 240 V it is rated 220 kA, at 415 V it is 154 kA, at 440 V it is 121 kA, and at 500 V and 690 V it is 17 kA. The voltage you are clearing at determines the SCCR you can claim downstream.

What accessories are included with 3VA1196-6EF32-0JH0?

The breaker ships with a shunt trip (STL) auxiliary release, two auxiliary switches, and one trip alarm switch (HQ) pre-installed. It also has a voltage trip indicator. No separate accessory order is needed for basic status feedback.

Where can I buy 3VA1196-6EF32-0JH0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

MPN
3VA1196-6EF32-0JH0