Skip to main content
Siemens 3VA1196-6GF42-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1196-6GF42-0AA0 SENTRON MCCB, 16 A, 4-Pole, 220 k

MPN3VA1196-6GF42-0AA0
Active

Siemens SENTRON 3VA1196-6GF42-0AA0, molded case circuit breaker, 16 A, 4-pole, TM240 overcurrent release, breaking capacity 220 kA at 240 V, 154 kA at 415 V, 121 kA at 440 V.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1196-6GF42-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON

Ratings

3VA1196-6GF42-0AA0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C16 A
Current at 45 °C16 A
Current at 50 °C16 A
Current at 55 °C16 A
Current at 60 °C15 A
Current at 65 °C15 A
Current at 70 °C15 A
Switching capacity classH
Breaking capacity at 240 V220 kA
Breaking capacity at 415 V154 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V17 kA
Breaking capacity at 690 V17 kA
Power loss, max.10.6 W

Protection & Trip Unit

3VA1196-6GF42-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA1196-6GF42-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1196-6GF42-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA1196-6GF42-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1196-6GF42-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width101.6 mm
Depth70 mm
Height (in)5.12 in
Width (in)4 in
Depth (in)2.76 in

Product details

Line protection MCCB with high interrupting capacity

The Siemens 3VA1196-6GF42-0AA0 is a SENTRON molded case circuit breaker (MCCB) rated for line protection, carrying a 16 A continuous current and a TM240 thermal-magnetic overcurrent release. The 4-pole design handles three-phase plus neutral, and the interrupting capacity reaches 220 kA at 240 V, 154 kA at 415 V, and 121 kA at 440 V — figures that suit high-fault industrial distribution where upstream transformer capacity or parallel sources drive available fault current above typical MCCB ratings. At 500 V and 690 V the rating drops to 17 kA, so verify the point-of-installation SCCR against those higher voltage levels.

Thermal derating and panel integration

Full 16 A rating holds from 40 °C up to 55 °C ambient; at 60 °C it derates to 15 A, and at 70 °C it holds at 15 A. The enclosure front carries IP40 protection — suitable for dry indoor panel environments where tools or fingers are the main concern, not washdown. Dimensions are 130 mm height, 101.6 mm width, and 70 mm depth, fitting standard MCCB mounting footprints. Maximum power loss is 10.6 W, which matters for thermal budgeting inside a sealed enclosure.

Frequently asked questions

Where can I buy 3VA1196-6GF42-0AA0 and how do I get a price?

This part is sourced to order against an RFQ through independent distribution. Submit a request for current availability and pricing.

What is the breaking capacity of 3VA1196-6GF42-0AA0 at 415 V?

The breaking capacity at 415 V is 154 kA.

MPN
3VA1196-6GF42-0AA0