Skip to main content
Siemens 3VA1216-4EF32-0AF0 — Molded Case Circuit Breakers (MCCB)

SENTRON 3VA1216-4EF32-0AF0 MCCB, 160A, 3-Pole, TM240, 121kA

MPN3VA1216-4EF32-0AF0

SENTRON 3VA1216-4EF32-0AF0, molded case circuit breaker, 3-pole, 160 A, TM240 thermal-magnetic release, line protection, 121 kA at 240 V.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3VA1216-4EF32-0AF0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA12164EF320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA1216-4EF32-0AF0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C156 A
Current at 60 °C151 A
Current at 65 °C147 A
Current at 70 °C142 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V52.5 kA
Breaking capacity at 500 V17 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.33 W
3VA1216-4EF32-0AF0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1216-4EF32-0AF0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1216-4EF32-0AF0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA1216-4EF32-0AF0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1216-4EF32-0AF0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height158 mm
Width105 mm
Depth70 mm
Height (in)6.22 in
Width (in)4.13 in
Depth (in)2.76 in

Product details

The SENTRON 3VA1216-4EF32-0AF0 is a 3-pole molded case circuit breaker (MCCB) rated 160 A continuous at 40 °C, fitted with a TM240 thermal-magnetic trip unit. The TM240 release gives you a fixed thermal curve and fixed magnetic pickup at 240 A, so there's no dial to mis-set on the floor.

This breaker clears 121 kA at 240 V, 75.6 kA at 415 V, 52.5 kA at 440 V, 17 kA at 500 V, and 11.9 kA at 690 V. Those are the SCCR values the breaker itself can interrupt without welding or rupturing.

Thermal derating — the real-world current you can pull

At 55 °C it's 156 A, at 60 °C it's 151 A, at 65 °C it's 147 A, and at 70 °C it's 142 A. If your panel ambient runs 55 °C because of adjacent drives or transformers, you lose 4 A — plan for it.

Built-in auxiliaries and panel fit

The 70 mm depth, 105 mm width, and 158 mm height fit standard SENTRON mounting footprints; if you're swapping a 3VA1 frame, the bolt pattern and bus-bar centers match.

If you're freezing a BOM or filling a spare-parts bin, this is the active part to specify.

Frequently asked questions

What is the interrupting capacity of 3VA1216-4EF32-0AF0 at 480 V?

At 440 V it clears 52.5 kA, which is the closest published value for a nominal 480 V system. At 415 V it clears 75.6 kA.

Will 3VA1216-4EF32-0AF0 drop into a panel specified for 3VA1110-5EF32-0AM0?

Both are 3VA1 frame MCCBs with the same 70 mm depth, 105 mm width, and 158 mm height, so the physical footprint and bus-bar centers match. The key difference is the trip rating: this one is 160 A with a TM240 release, while the 3VA1110-5EF32-0AM0 is a lower-current variant. Verify the load current before swapping.

Where can I buy 3VA1216-4EF32-0AF0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commitment.

MPN
3VA1216-4EF32-0AF0