Siemens 3VA1216-4EF32-0BA0 — Molded Case Circuit Breakers (MCCB)

Siemens SENTRON 3VA1216-4EF32-0BA0 MCCB, 160 A, 3-Pole, 121

MPN3VA1216-4EF32-0BA0

Siemens SENTRON 3VA1216-4EF32-0BA0, molded case circuit breaker (MCCB), 3-pole, 160 A rated continuous current (Iu), TM240 thermal-magnetic release, interrupting capacity 121 kA at 240 V AC, with integrated undervoltage release (UVR).

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3VA1216-4EF32-0BA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA1216-4EF32-0BA0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C155.6 A
Current at 60 °C151.2 A
Current at 65 °C146.8 A
Current at 70 °C142.4 A
Switching capacity classN
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V25 kA
Breaking capacity at 690 V11.9 kA
3VA1216-4EF32-0BA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
3VA1216-4EF32-0BA0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1216-4EF32-0BA0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1216-4EF32-0BA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1216-4EF32-0BA0 — Mechanical
ParameterValue
Height158 mm
Width105 mm
Depth70 mm

Product details

The Siemens SENTRON 3VA1216-4EF32-0BA0 is a 3-pole molded case circuit breaker (MCCB) rated for line protection, carrying a continuous current Iu of 160 A at 40 °C through 50 °C ambient — no derating needed in a standard 50 °C panel environment. At 55 °C it still holds 155.6 A, and at 70 °C it delivers 142.4 A, so the thermal curve is flat across most normal operating conditions.

Built-in undervoltage release — no add-on module needed

No auxiliary contact version is fitted, and there is no communication module or ground-fault monitoring on this build.

Dimensions: 105 mm wide, 158 mm high, 70 mm deep. Depth of 70 mm means it clears most standard gland-plate depths without protruding past the enclosure door.

Frequently asked questions

What is the interrupting capacity of 3VA1216-4EF32-0BA0 at 415 V?

75.6 kA at 415 V AC, which provides strong selectivity headroom on typical 50 kA or 65 kA services.

Does this MCCB include an undervoltage release?

Yes, it ships with an integrated undervoltage release (UVR), part code 3VA9608-0BB11, so no separate add-on module is required.

Where can I buy the 3VA1216-4EF32-0BA0?

Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

MPN