Skip to main content
Siemens 3VA1216-4EF32-0BC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1216-4EF32-0BC0 SENTRON MCCB, 160 A, 3-Pole

MPN3VA1216-4EF32-0BC0

Siemens SENTRON 3VA molded case circuit breaker, 3VA1216-4EF32-0BC0, 3-pole, 160 A rated current, 121 kA breaking capacity at 240 V, line protection design with undervoltage release.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1216-4EF32-0BC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA12164EF320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1216-4EF32-0BC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C156 A
Current at 60 °C151 A
Current at 65 °C147 A
Current at 70 °C142 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V52.5 kA
Breaking capacity at 500 V17 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.35.5 W
3VA1216-4EF32-0BC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1216-4EF32-0BC0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1216-4EF32-0BC0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA1216-4EF32-0BC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1216-4EF32-0BC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height158 mm
Width105 mm
Depth70 mm
Height (in)6.22 in
Width (in)4.13 in
Depth (in)2.76 in

Product details

The Siemens SENTRON 3VA1216-4EF32-0BC0 is a 3-pole molded case circuit breaker (MCCB) rated for line protection, built around a 160 A frame that holds its full rating from 40 °C through 50 °C without derating. Breaking capacity is the other headline: 121 kA at 240 V, 75.6 kA at 415 V, 52.5 kA at 440 V, 17 kA at 500 V, and 11.9 kA at 690 V. The 70 mm depth, 105 mm width, and 158 mm height fit standard SENTRON 3VA panel cutouts; if you are replacing an older 3VA1 frame the footprint is the same.

Internal configuration and auxiliaries

This variant ships with the undervoltage release (UVR) factory-installed and two HQ auxiliary switches wired in — so it is ready for a safety circuit that drops the breaker on loss of control voltage, and for remote status feedback. The base switch is order code 3VA12164EF320AA0; the UVR is the design-of-the-auxiliary-release type, meaning it is integrated, not a field-add-on kit. No ground-fault monitoring, no communication function, no voltage trigger, and no trip indicator on this order code. It is a straight line-protection breaker with undervoltage release — clean, no extra electronics to fail.

Frequently asked questions

What is the breaking capacity of 3VA1216-4EF32-0BC0 at 415 V?

The breaking capacity at 415 V is 75.6 kA, which covers most industrial main-switchboard fault levels in 400 V systems.

How do I get current pricing and availability for 3VA1216-4EF32-0BC0?

This part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is the rated current of 3VA1216-4EF32-0BC0 at 40 °C?

The rated current at 40 °C is 160 A, and it holds that same 160 A at 45 °C and 50 °C before beginning to derate at 55 °C.

MPN
3VA1216-4EF32-0BC0