Skip to main content
Siemens 3VA1216-4EF42-0BA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1216-4EF42-0BA0 SENTRON MCCB, 160A 4-Pole, 121 kA

MPN3VA1216-4EF42-0BA0

Siemens SENTRON 3VA1216-4EF42-0BA0, molded case circuit breaker, 4-pole, 160 A (40 °C), 121 kA at 240 V, undervoltage release, line protection design.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1216-4EF42-0BA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA12164EF420AA0

Ratings

3VA1216-4EF42-0BA0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C156 A
Current at 60 °C151 A
Current at 65 °C147 A
Current at 70 °C142 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V52.5 kA
Breaking capacity at 500 V17 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.35.5 W

Protection & Trip Unit

3VA1216-4EF42-0BA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA1216-4EF42-0BA0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1216-4EF42-0BA0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA1216-4EF42-0BA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1216-4EF42-0BA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height158 mm
Width140 mm
Depth70 mm
Height (in)6.22 in
Width (in)5.51 in
Depth (in)2.76 in

Product details

SENTRON 3VA — 160 A, 4-Pole, 121 kA Breaking Capacity

The Siemens SENTRON 3VA1216-4EF42-0BA0 is a 4-pole molded case circuit breaker rated for 160 A continuous at 40 °C, with the full 160 A holding through 50 °C before it starts to derate — 156 A at 55 °C, 151 A at 60 °C, 147 A at 65 °C, and 142 A at 70 °C. Its interrupting capacity hits 121 kA at 240 V, 75.6 kA at 415 V, 52.5 kA at 440 V, 17 kA at 500 V, and 11.9 kA at 690 V — high-fault ratings that give you selectivity headroom in a main or feeder position without cascading upstream. This MCCB is designed for line protection and ships with an integrated undervoltage release (UVR), so it drops the load on loss of control voltage — no separate shunt trip module needed.

Panel Fit and Integration

At 70 mm deep × 140 mm wide × 158 mm high, this 4-pole breaker fits standard SENTRON 3VA mounting footprints — compatible with the same busbar and accessory system as the rest of the series. The TM240 thermal-magnetic trip unit is fixed inside, so no field-interchangeable trip block — what you see is what protects the feeder. Maximum power loss is 35.5 W; factor that into enclosure ventilation if the panel is densely packed.

Frequently asked questions

Does the 3VA1216-4EF42-0BA0 include an undervoltage release?

Yes, it ships with an integrated undervoltage release (UVR) as standard, so it drops the load automatically on loss of control voltage.

MPN
3VA1216-4EF42-0BA0