Siemens 3VA1216-5EE32-0AA0 SENTRON MCCB, 160 A, 3-Pole, TM22

MPN3VA1216-5EE32-0AA0

Siemens SENTRON 3VA1216-5EE32-0AA0, molded case circuit breaker, 3-pole, 160 A, TM220 thermal-magnetic release, line protection, 70 x 105 x 158 mm.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1216-5EE32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA1216-5EE32-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C156 A
Current at 60 °C151 A
Current at 65 °C147 A
Current at 70 °C142 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 500 V30 kA
Breaking capacity at 690 V17 kA
Power loss, max.33 W
3VA1216-5EE32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM220
Overcurrent protection functionLI
Ground-fault monitoringWithout
3VA1216-5EE32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1216-5EE32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1216-5EE32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1216-5EE32-0AA0 — Mechanical
ParameterValue
Height158 mm
Width105 mm
Depth70 mm
Height (in)6.22 in
Width (in)4.13 in
Depth (in)2.76 in

Product details

The interrupting capacity hits 187 kA at 240 V AC, 121 kA at 415 V, and still holds 17 kA at 690 V, so it handles high-fault scenarios downstream of a transformer without cascading upstream breakers. The IP40 front protection means the breaker face is protected against solid objects over 1 mm, but the enclosure itself must be rated for the installation environment — this is a panel-mount component, not a standalone outdoor unit. Power loss at full load runs 33 W maximum, worth considering for thermal management in a densely packed enclosure.

Current derating and thermal limits

Above that, it derates: 156 A at 55 °C, 151 A at 60 °C, 147 A at 65 °C, and 142 A at 70 °C.

Dimensions are 105 mm wide, 158 mm high, 70 mm deep.

Frequently asked questions

Where can I buy 3VA1216-5EE32-0AA0 and get a price?

This MCCB is sourced and quoted to order against an RFQ through independent distribution. Submit a request for current pricing and availability — confirmed at quote time.

What is the interrupting capacity of 3VA1216-5EE32-0AA0 at different voltages?

187 kA at 240 V AC, 121 kA at 415 V, 75.6 kA at 440 V, 30 kA at 500 V, and 17 kA at 690 V. The 187 kA figure at 240 V makes it suitable for high-fault installations near large transformers.

Will 3VA1216-5EE32-0AA0 drop into a panel specified for 3VA1112-5EE32-0AA0?

Both are 3-pole SENTRON 3VA breakers with the same 105 mm width, 158 mm height, and 70 mm depth. The 3VA1216 carries a higher 160 A frame rating versus the 3VA1112's lower rating, so it will physically fit the same mounting footprint but requires checking that the feeder and bus bars are sized for 160 A.

MPN