Skip to main content
Siemens 3VA1216-5EF32-0BA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1216-5EF32-0BA0 SENTRON MCCB, 160 A, 3-Pole

MPN3VA1216-5EF32-0BA0

Siemens SENTRON 3VA1 series, 3-pole molded case circuit breaker, 160 A at 40 °C, TM240 thermal-magnetic release, undervoltage release, 70 mm depth.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3VA1216-5EF32-0BA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA12165EF320AA0
3VA1216-5EF32-0BA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C156 A
Current at 60 °C151 A
Current at 65 °C147 A
Current at 70 °C142 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 500 V30 kA
Breaking capacity at 690 V17 kA
Power loss, max.35.5 W
3VA1216-5EF32-0BA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1216-5EF32-0BA0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1216-5EF32-0BA0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1216-5EF32-0BA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1216-5EF32-0BA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height158 mm
Width105 mm
Depth70 mm
Height (in)6.22 in
Width (in)4.13 in
Depth (in)2.76 in

Product details

Rated 160 A continuous at 40 °C, it holds that full rating through 50 °C before derating to 156 A at 55 °C and 142 A at 70 °C — useful to know if the breaker sits near other heat sources in a crowded panel. Interrupting capacity runs 187 kA at 240 V, 121 kA at 415 V, and 75.6 kA at 440 V — high enough for most distribution boards downstream of a large transformer.

Frequently asked questions

What is the interrupting capacity of this MCCB?

187 kA at 240 V, 121 kA at 415 V, 75.6 kA at 440 V, 30 kA at 500 V, and 17 kA at 690 V.

Where can I buy 3VA1216-5EF32-0BA0?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing confirmed at quote time.

Does this breaker include an undervoltage release?

Yes, it is equipped with an undervoltage release (UVR) as standard.

MPN