Siemens 3VA1216-6EF32-0KF0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1216-6EF32-0KF0 SENTRON MCCB, 32 A, 4-Pole, 220 k

MPN3VA1216-6EF32-0KF0

Siemens SENTRON 3VA1216-6EF32-0KF0, molded case circuit breaker, 4-pole, 32 A rated continuous current, TM240 overcurrent release, shunt trip, 220 kA at 240 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3VA1216-6EF32-0KF0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA1216-6EF32-0KF0 — Ratings
ParameterValue
Number of poles4
Current at 40 °C32 A
Current at 45 °C32 A
Current at 50 °C32 A
Current at 60 °C31 A
Current at 65 °C30 A
Current at 70 °C30 A
Switching capacity classH
Breaking capacity at 240 V220 kA
Breaking capacity at 415 V154 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V17 kA
Breaking capacity at 690 V17 kA
3VA1216-6EF32-0KF0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
3VA1216-6EF32-0KF0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1216-6EF32-0KF0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA1216-6EF32-0KF0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1216-6EF32-0KF0 — Mechanical
ParameterValue
Height130 mm
Width (in)4 in

Product details

Breaking capacity is voltage-dependent: 220 kA at 240 V AC, 154 kA at 415 V, 121 kA at 440 V, and 17 kA at both 500 V and 690 V. The 4-pole design with 100% N-conductor protection means the neutral pole is fully rated and trips with the phase poles — no derating needed for unbalanced loads or harmonic-rich circuits. This matters for panels feeding non-linear loads like VFD banks or UPS inputs where neutral current can approach phase current.

Thermal derating and temperature range

At 60 °C it derates to 31 A, and at 65 °C and 70 °C it settles at 30 A.

Physical integration and panel fit

Height is 130 mm; width is 4 inches (101.6 mm). The 4-inch width is a standard US panel cutout dimension — this breaker fits existing 4-inch-spaced busbar or lug layouts without adapter plates. That DC rating opens up battery-bank or DC-bus applications in the 600 V class, though the DC breaking capacity should be verified against the device manual per the manufacturer's note.

Frequently asked questions

What is the breaking capacity of 3VA1216-6EF32-0KF0 at 240 V?

The listed breaking capacity at 240 V is 220 kA. At 415 V it is 154 kA, at 440 V it is 121 kA, and at 500 V and 690 V it is 17 kA.

What is the height of this MCCB?

The height is 130 mm. Width is 4 inches (101.6 mm), matching standard US panel cutout spacing.

Where can I buy 3VA1216-6EF32-0KF0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock figures or lead-time numbers are published here.

Does 3VA1216-6EF32-0KF0 include a shunt trip?

Yes, the design of the auxiliary release is a shunt trip (STL). The integrated auxiliary trip order code is 3VA9688-0BL33. There is no undervoltage release.