Skip to main content
Siemens 3VA1220-4EF32-0AF0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1220-4EF32-0AF0 SENTRON MCCB, 200 A, 3-Pole, 121

MPN3VA1220-4EF32-0AF0

Siemens SENTRON 3VA molded case circuit breaker, 3VA1220-4EF32-0AF0, 3-pole, 200 A rated continuous current (Iu), TM240 thermal-magnetic release, line protection version, 121 kA breaking capacity at 240 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3VA1220-4EF32-0AF0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA1220-4EF32-0AF0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C200 A
Current at 45 °C200 A
Current at 50 °C200 A
Current at 55 °C194 A
Current at 60 °C188 A
Current at 65 °C182 A
Current at 70 °C176 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V25 kA
Breaking capacity at 690 V11.9 kA
3VA1220-4EF32-0AF0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
3VA1220-4EF32-0AF0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1220-4EF32-0AF0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA1220-4EF32-0AF0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1220-4EF32-0AF0 — Mechanical
ParameterValue
Height158 mm
Width105 mm
Depth70 mm

Product details

The Siemens 3VA1220-4EF32-0AF0 is a SENTRON molded case circuit breaker (MCCB) in the 3VA platform, sized for 200 A continuous duty and configured as a 3-pole line-protection device with a TM240 thermal-magnetic trip unit. Breaking capacity is the headline selector here: 121 kA at 240 V, 75.6 kA at 415 V, 25 kA at 440 V, and 11.9 kA at 690 V — so the same breaker covers high-fault 240 V service entrances and 400 V distribution boards without stepping up to a larger frame. The thermal derating curve is published across the full ambient range: 200 A flat from 40 °C to 50 °C, then 194 A at 55 °C, 188 A at 60 °C, 182 A at 65 °C, and 176 A at 70 °C. The auxiliary contact block is a 1 NO + 1 NC auxiliary switch paired with a separate trip-alarm switch (HQ configuration), giving you both position indication and fault annunciation on a single breaker.

Dimensions: 105 mm wide, 158 mm high, 70 mm deep. The -25 °C floor matters for unheated outdoor cabinets in temperate climates — the breaker is rated to close and carry load at that low end.

MPN