Skip to main content
Siemens 3VA1220-4EF32-0AJ0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1220-4EF32-0AJ0 SENTRON MCCB, 200 A, 3-Pole, 121

MPN3VA1220-4EF32-0AJ0

Siemens SENTRON 3VA1220-4EF32-0AJ0, molded case circuit breaker, 3-pole, 200 A, TM240 thermal-magnetic release, 121 kA at 240 V, 75.6 kA at 415 V.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3VA1220-4EF32-0AJ0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA12204EF320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB11
3VA1220-4EF32-0AJ0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Current at 40 °C200 A
Current at 45 °C200 A
Current at 50 °C200 A
Current at 55 °C194 A
Current at 60 °C188 A
Current at 65 °C182 A
Current at 70 °C176 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V52.5 kA
Breaking capacity at 500 V17 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.42 W
3VA1220-4EF32-0AJ0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
3VA1220-4EF32-0AJ0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1220-4EF32-0AJ0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA1220-4EF32-0AJ0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1220-4EF32-0AJ0 — Mechanical
ParameterValue
Height158 mm
Width105 mm
Depth70 mm
Height (in)6.22 in
Width (in)4.13 in
Depth (in)2.76 in

Product details

The Siemens SENTRON 3VA1220-4EF32-0AJ0 is a 3-pole molded case circuit breaker rated for 200 A continuous current at 40 °C, with a TM240 thermal-magnetic overcurrent release. The interrupting ratings are the headline: 121 kA at 240 V, 75.6 kA at 415 V, 52.5 kA at 440 V, 17 kA at 500 V, and 11.9 kA at 690 V. The continuous current holds flat at 200 A from 40 °C through 50 °C, then derates to 194 A at 55 °C, 188 A at 60 °C, 182 A at 65 °C, and 176 A at 70 °C. That derating curve means in a warm panel — say 55 °C internal ambient — you still get 194 A before the thermal element starts to drift.

Dimensions: 105 mm wide, 158 mm high, 70 mm deep. The trip indicator is present, so a visual check confirms the breaker tripped on fault versus being manually opened.

For a BOM line or a panel spare, this is a straight-forward source. The 3VA series is Siemens' standard MCCB platform, so availability through distribution is routine.

Frequently asked questions

Where can I buy 3VA1220-4EF32-0AJ0 and get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm number.

What is the interrupting rating of 3VA1220-4EF32-0AJ0 at 415 V?

75.6 kA at 415 V, which covers most industrial 400 V class feeder applications without upstream fusing.

What compliance documentation does Siemens provide for this MCCB?

The SENTRON 3VA series carries UL, IEC, and CSA certifications standard for the line. RoHS and REACH declarations are available through Siemens' documentation portal.

MPN
3VA1220-4EF32-0AJ0