Siemens SENTRON 3VA1220-4EF32-0CH0, molded case circuit breaker, 3-pole, 200 A rated continuous current Iu, line protection version, TM240 overcurrent release, undervoltage release included, 70 mm depth.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1220-4EF32-0CH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA1220-4EF32-0CH0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C200 A
Current at 45 °C200 A
Current at 50 °C200 A
Current at 55 °C194 A
Current at 60 °C188 A
Current at 65 °C182 A
Current at 70 °C176 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V25 kA
Breaking capacity at 690 V11.9 kA
3VA1220-4EF32-0CH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
3VA1220-4EF32-0CH0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1220-4EF32-0CH0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA1220-4EF32-0CH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1220-4EF32-0CH0 — Mechanical
ParameterValue
Height158 mm
Width105 mm
Depth70 mm

Product details

The TM240 thermal-magnetic release handles the overload and short-circuit sensing; there's no electronic trip unit to program or power.

Breaking capacity at the voltages you actually see

This breaker's interrupting rating is voltage-dependent, and the numbers matter for selectivity coordination. At 240 V it clears 121 kA; at 415 V it's 75.6 kA; at 440 V it drops to 25 kA; and at 690 V it's 11.9 kA. If your panel feeds a 480 V distribution bus, the 440 V figure (25 kA) is the one to compare against your available fault current — that's the limiting case for most North American commercial installations. The 690 V rating covers the European 400 V line-to-line with headroom.

Thermal derating and environment

At 55 °C it drops to 194 A, then 188 A at 60 °C, 182 A at 65 °C, and 176 A at 70 °C. Front-face protection is IP40, so it's splash-resistant from the front in a closed panel but not washdown-rated.

Frequently asked questions

What is 3VA1220-4EF32-0CH0's listed depth?

The listed depth is 70 mm. Overall dimensions are 158 mm tall by 105 mm wide by 70 mm deep, fitting standard MCCB panel cutouts.