Skip to main content
Siemens 3VA1220-4EF32-0DE0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1220-4EF32-0DE0 SENTRON MCCB, 200 A, 3-Pole, Line

MPN3VA1220-4EF32-0DE0

Siemens SENTRON 3VA1220-4EF32-0DE0, 3-pole molded case circuit breaker, 200 A rated current, line protection with TM240 overcurrent release and undervoltage release, 121 kA interrupting at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1220-4EF32-0DE0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA12204EF320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1220-4EF32-0DE0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Current at 40 °C200 A
Current at 45 °C200 A
Current at 50 °C200 A
Current at 55 °C194 A
Current at 60 °C188 A
Current at 65 °C182 A
Current at 70 °C176 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V52.5 kA
Breaking capacity at 500 V17 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.44.5 W
3VA1220-4EF32-0DE0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
3VA1220-4EF32-0DE0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1220-4EF32-0DE0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts4
3VA1220-4EF32-0DE0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1220-4EF32-0DE0 — Mechanical
ParameterValue
Height158 mm
Width105 mm
Depth70 mm
Height (in)6.22 in
Width (in)4.13 in
Depth (in)2.76 in

Product details

Its TM240 thermal-magnetic overcurrent release handles the overload and short-circuit trip curve, while the integrated undervoltage release (UVR) drops the breaker if control voltage is lost — a standard requirement for safety disconnects in refrigeration compressor circuits and other PSM-monitored equipment.

Interrupting capacity — the real-world fault clearance

This breaker clears 121 kA at 240 V, 75.6 kA at 415 V, 52.5 kA at 440 V, 17 kA at 500 V, and 11.9 kA at 690 V.

Thermal derating — how it runs cold and stays cold

Rated current holds flat at 200 A from 40 °C through 50 °C, then derates to 194 A at 55 °C, 188 A at 60 °C, 182 A at 65 °C, and 176 A at 70 °C. For a cold-storage or freezer line where ambient stays near 0 °C, the breaker runs well below its thermal limit — no derating concern. In a hot panel (55 °C+), the 6 A step per 5 °C is predictable and easy to factor into the BOM.

Panel fit and auxiliary contacts

Frequently asked questions

Where can I buy 3VA1220-4EF32-0DE0 and how is it quoted?

This part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at the time of quote.

What is the interrupting capacity of 3VA1220-4EF32-0DE0 at 415 V?

At 415 V the breaker clears 75.6 kA.

Does 3VA1220-4EF32-0DE0 include an undervoltage release?

Yes, it is factory-fitted with an undervoltage release (UVR).

MPN
3VA1220-4EF32-0DE0