Skip to main content
Siemens 3VA1220-4EF42-0CC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1220-4EF42-0CC0 SENTRON MCCB, 200 A, 4-Pole, 121

MPN3VA1220-4EF42-0CC0

Siemens SENTRON 3VA1220-4EF42-0CC0, 4-pole molded case circuit breaker, 200 A at 40 °C, 121 kA at 240 V, line protection, undervoltage release.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1220-4EF42-0CC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA12204EF420AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1220-4EF42-0CC0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C200 A
Current at 45 °C200 A
Current at 50 °C200 A
Current at 55 °C194 A
Current at 60 °C188 A
Current at 65 °C182 A
Current at 70 °C176 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V52.5 kA
Breaking capacity at 500 V17 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.44.5 W
3VA1220-4EF42-0CC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1220-4EF42-0CC0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1220-4EF42-0CC0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA1220-4EF42-0CC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1220-4EF42-0CC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height158 mm
Width140 mm
Depth70 mm
Height (in)6.22 in
Width (in)5.51 in
Depth (in)2.76 in

Product details

It carries a continuous current of 200 A at 40 °C, with the same rating holding at 45 °C and 50 °C before gradual derating kicks in — 194 A at 55 °C, 188 A at 60 °C, 182 A at 65 °C, and 176 A at 70 °C. That thermal profile means it's comfortable in a warm enclosure without losing much headroom.

Interrupting capacity

Short-circuit breaking capacity is 121 kA at 240 V, 75.6 kA at 415 V, 52.5 kA at 440 V, 17 kA at 500 V, and 11.9 kA at 690 V. That's a serious interrupting rating — it handles high fault currents at common distribution voltages without cascading upstream. Panel builders should check that the upstream protective device coordinates with these levels; the 415 V figure of 75.6 kA covers most European industrial mains.

It's a straight line-protection MCCB with undervoltage release, designed for fixed installation in distribution boards.

Frequently asked questions

Where can I buy 3VA1220-4EF42-0CC0 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is 3VA1220-4EF42-0CC0's interrupting capacity at 415 V?

The interrupting capacity at 415 V is 75.6 kA, which covers most European industrial mains fault levels.

What is the rated current of 3VA1220-4EF42-0CC0 at 40 °C?

The continuous current rating is 200 A at 40 °C, with derating starting above 50 °C.

MPN
3VA1220-4EF42-0CC0