Siemens 3VA1220-4EF42-0KA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1220-4EF42-0KA0 SENTRON MCCB, 200 A, 4-Pole, 121

MPN3VA1220-4EF42-0KA0

Siemens SENTRON, Molded case circuit breaker, 3VA1220-4EF42-0KA0, 4-pole, 200 A at 40 °C, TM240 release, shunt trip, 121 kA at 240 V.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1220-4EF42-0KA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA12204EF420AA0

Ratings

3VA1220-4EF42-0KA0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C200 A
Current at 45 °C200 A
Current at 50 °C200 A
Current at 55 °C194 A
Current at 60 °C188 A
Current at 65 °C182 A
Current at 70 °C176 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V52.5 kA
Breaking capacity at 500 V17 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.42 W

Protection & Trip Unit

3VA1220-4EF42-0KA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA1220-4EF42-0KA0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1220-4EF42-0KA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA1220-4EF42-0KA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1220-4EF42-0KA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height158 mm
Width140 mm
Depth70 mm
Height (in)6.22 in
Width (in)5.51 in
Depth (in)2.76 in

Product details

What this MCCB carries — and what it means on a panel

The Siemens 3VA1220-4EF42-0KA0 is a 4-pole SENTRON molded case circuit breaker rated 200 A at 40 °C, with a TM240 thermal-magnetic release and an integrated shunt trip (STL) for remote tripping. The 121 kA breaking capacity at 240 V tells you it can clear a fault up to that level without upstream fuses or a bigger main — useful for high-fault service entrances or distribution panels where SCCR headroom matters. At 415 V it still breaks 75.6 kA, and at 690 V it holds 11.9 kA, so it's not a one-voltage pony; the ratings follow the voltage curve you'd expect from a frame this size.

Thermal derating — the real current you can run

The 200 A rating holds steady through 50 °C ambient. Above that it starts to step down: 194 A at 55 °C, 188 A at 60 °C, 182 A at 65 °C, and 176 A at 70 °C. If the panel runs hot — say a packed enclosure near a furnace line — the 176 A floor at 70 °C is the number to design to, not the 200 A nameplate. The TM240 release is set for a 240 A frame, so the breaker itself has headroom; the thermal curve is what governs continuous load.

Dimensions and panel fit

The case measures 158 mm high, 140 mm wide, and 70 mm deep. That 70 mm depth is shallow enough to clear a standard 200 mm deep enclosure backpan without the breaker protruding past the gland plate. The 140 mm width for a 4-pole means each pole takes about 35 mm — typical for this frame class. Mounting holes and bus-bar slot pattern match other SENTRON 3VA breakers, so swapping a 3-pole for this 4-pole in the same lineup usually just means shifting the bus work one phase over.

What the approvals and ratings tell a specifier

Rated insulation voltage is 800 V, so it's comfortable on 480 V and 600 V class systems with margin. Operating temperature range is -25 °C to 70 °C; storage range is -40 °C to 80 °C. The breaker is designed for line protection (not motor protection — that's what the TM thermal curve plus magnetic trip is set up for). No undervoltage release, no ground-fault monitoring, no communication function on this variant. The supplied basic switch code is 3VA12204EF420AA0 if you need to cross-reference internal parts.

Frequently asked questions

What is the breaking capacity of 3VA1220-4EF42-0KA0 at different voltages?

121 kA at 240 V, 75.6 kA at 415 V, 52.5 kA at 440 V, 17 kA at 500 V, and 11.9 kA at 690 V. The high 240 V rating makes it suitable for service-entrance or main-breaker duty where fault current is highest on the low-voltage side of a transformer.

Where can I buy 3VA1220-4EF42-0KA0 and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock figures or lead-time numbers published here, but it's a standard catalog item so lead times are typically reasonable for a current-production MCCB.

Will 3VA1220-4EF42-0KA0 drop into a panel that was specified around 5SQ2670-2YA63 without rewiring?

The 5SQ2670-2YA63 is a different manufacturer's MCCB with a different mounting footprint and bus-bar pattern. The 3VA1220-4EF42-0KA0 has its own 140 mm wide, 158 mm high, 70 mm deep case dimensions and SENTRON-specific mounting hole locations. A direct mechanical swap without panel modification is unlikely; expect to drill new mounting holes and rework the bus connections.

MPN
3VA1220-4EF42-0KA0