Skip to main content
Siemens 3VA1220-4GF42-0AE0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1220-4GF42-0AE0 SENTRON MCCB, 200 A, 4-Pole, TM24

MPN3VA1220-4GF42-0AE0

Siemens SENTRON 3VA1220-4GF42-0AE0, 4-pole molded case circuit breaker, 200 A rated current, TM240 thermal-magnetic release, line protection design.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1220-4GF42-0AE0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA12204GF420AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1220-4GF42-0AE0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C200 A
Current at 45 °C200 A
Current at 50 °C200 A
Current at 55 °C194 A
Current at 60 °C188 A
Current at 65 °C182 A
Current at 70 °C176 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V52.5 kA
Breaking capacity at 500 V17 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.42 W
3VA1220-4GF42-0AE0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1220-4GF42-0AE0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1220-4GF42-0AE0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts4
3VA1220-4GF42-0AE0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1220-4GF42-0AE0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height158 mm
Width140 mm
Depth70 mm
Height (in)6.22 in
Width (in)5.51 in
Depth (in)2.76 in

Product details

Rated interrupting capacity reaches 121 kA at 240 V AC, dropping to 75.6 kA at 415 V, 52.5 kA at 440 V, 17 kA at 500 V, and 11.9 kA at 690 V.

Thermal derating curve

Derating begins at 55 °C (194 A), then 188 A at 60 °C, 182 A at 65 °C, and 176 A at 70 °C. Panel ambient temperature inside the enclosure — not the room — is what determines the usable continuous current; a crowded cabinet at 60 °C knocks off 12 A from the nameplate.

The 140 mm width for a 4-pole frame is standard for SENTRON 3VA molded case breakers at this rating — verify the mounting footprint against the existing backplate or DIN-rail adapter before committing the panel layout. Maximum power dissipation is 42 W. In a sealed, non-ventilated enclosure that heat must be accounted for in the thermal budget; adjacent devices may need spacing or forced airflow.

Frequently asked questions

What is the breaking capacity of 3VA1220-4GF42-0AE0 at 415 V?

75.6 kA at 415 V AC. This is the interrupting rating that governs fault clearing at common European distribution voltages.

What overcurrent release does this MCCB use?

A TM240 thermal-magnetic release. This is a fixed, non-adjustable trip unit — no dial or plug-in module for changing the curve.

Where can I buy 3VA1220-4GF42-0AE0 and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time.

MPN