Skip to main content
Siemens 3VA1220-4GF42-0AE0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1220-4GF42-0AE0 SENTRON MCCB, 200 A, 4-Pole, TM24

MPN3VA1220-4GF42-0AE0

Siemens SENTRON 3VA1220-4GF42-0AE0, 4-pole molded case circuit breaker, 200 A rated current, TM240 thermal-magnetic release, line protection design.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1220-4GF42-0AE0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA12204GF420AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12

Ratings

3VA1220-4GF42-0AE0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C200 A
Current at 45 °C200 A
Current at 50 °C200 A
Current at 55 °C194 A
Current at 60 °C188 A
Current at 65 °C182 A
Current at 70 °C176 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V52.5 kA
Breaking capacity at 500 V17 kA
Breaking capacity at 690 V11.9 kA
Power loss, max.42 W

Protection & Trip Unit

3VA1220-4GF42-0AE0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA1220-4GF42-0AE0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1220-4GF42-0AE0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts4

Environmental

3VA1220-4GF42-0AE0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1220-4GF42-0AE0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height158 mm
Width140 mm
Depth70 mm
Height (in)6.22 in
Width (in)5.51 in
Depth (in)2.76 in

Product details

The Siemens SENTRON 3VA1220-4GF42-0AE0 is a 4-pole molded case circuit breaker (MCCB) rated at 200 A continuous current, fitted with a TM240 thermal-magnetic overcurrent release. It is designed for line protection in distribution panels and switchgear assemblies where a fixed, non-adjustable trip curve is acceptable.

Breaking capacity and selectivity

Rated interrupting capacity reaches 121 kA at 240 V AC, dropping to 75.6 kA at 415 V, 52.5 kA at 440 V, 17 kA at 500 V, and 11.9 kA at 690 V. These values govern fault-clearing capability at the point of common coupling — match them against the available fault current at the breaker's installation point to confirm adequate SCCR headroom for downstream coordination. Insulation voltage is rated at 800 V, so the breaker supports 690 V line-to-line systems with full dielectric margin.

Thermal derating curve

At 40 °C, 45 °C, and 50 °C the breaker carries its full 200 A rating. Derating begins at 55 °C (194 A), then 188 A at 60 °C, 182 A at 65 °C, and 176 A at 70 °C. Panel ambient temperature inside the enclosure — not the room — is what determines the usable continuous current; a crowded cabinet at 60 °C knocks off 12 A from the nameplate.

Physical fit and integration

Dimensions are 158 mm high, 140 mm wide, and 70 mm deep. The 140 mm width for a 4-pole frame is standard for SENTRON 3VA molded case breakers at this rating — verify the mounting footprint against the existing backplate or DIN-rail adapter before committing the panel layout. Maximum power dissipation is 42 W. In a sealed, non-ventilated enclosure that heat must be accounted for in the thermal budget; adjacent devices may need spacing or forced airflow.

Frequently asked questions

What is the breaking capacity of 3VA1220-4GF42-0AE0 at 415 V?

75.6 kA at 415 V AC. This is the interrupting rating that governs fault clearing at common European distribution voltages.

What overcurrent release does this MCCB use?

A TM240 thermal-magnetic release. This is a fixed, non-adjustable trip unit — no dial or plug-in module for changing the curve.

Where can I buy 3VA1220-4GF42-0AE0 and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time.

MPN
3VA1220-4GF42-0AE0