Skip to main content
Siemens 3VA1220-4GF42-0BH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1220-4GF42-0BH0 SENTRON MCCB, 200 A, 4-Pole, 121

MPN3VA1220-4GF42-0BH0

Siemens SENTRON 3VA1220-4GF42-0BH0, Molded case circuit breaker, Line protection, 4 poles, 200 A, TM240 release, 121 kA at 240 V, 75.6 kA at 415 V.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1220-4GF42-0BH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AB12

Ratings

3VA1220-4GF42-0BH0 — Ratings
ParameterValue
Number of poles4
Current at 40 °C200 A
Current at 45 °C200 A
Current at 50 °C200 A
Current at 55 °C194 A
Current at 60 °C188 A
Current at 65 °C182 A
Current at 70 °C176 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V25 kA
Breaking capacity at 690 V11.9 kA

Protection & Trip Unit

3VA1220-4GF42-0BH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240

Construction & Connection

3VA1220-4GF42-0BH0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1220-4GF42-0BH0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3

Environmental

3VA1220-4GF42-0BH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1220-4GF42-0BH0 — Mechanical
ParameterValue
Height158 mm
Width140 mm
Depth70 mm

Product details

What this MCCB is and what it does

The Siemens SENTRON 3VA1220-4GF42-0BH0 is a 4-pole molded case circuit breaker (MCCB) rated for line protection, carrying a continuous current Iu of 200 A at 40 °C through 50 °C, with a TM240 thermal-magnetic overcurrent release. Its interrupting capacity is 121 kA at 240 V, 75.6 kA at 415 V, 25 kA at 440 V, and 11.9 kA at 690 V — figures that define the maximum fault current it can safely clear at each voltage level without upstream coordination failure. The breaker is fitted with an undervoltage release (UVR) and comes with 2 auxiliary switches plus 1 trip alarm switch (HQ configuration), giving the panel builder both status feedback and a shunt-trip path for remote or safety-circuit dropout. It is a 100%-rated N-conductor protection design, meaning the neutral pole is fully rated to carry the same current as the phase poles — no derating needed for 4-wire systems with high neutral harmonics.

Thermal derating and real-world current capacity

The 200 A rating holds flat from 40 °C to 50 °C ambient. Above that, it derates: 194 A at 55 °C, 188 A at 60 °C, 182 A at 65 °C, and 176 A at 70 °C. If your panel ambient runs hot, size the load to the derated figure, not the nameplate 200 A.

Physical fit and panel integration

Dimensions are 158 mm high, 140 mm wide, and 70 mm deep. The 70 mm depth is shallow enough for most standard distribution panels without interfering with the rear wiring trough or busbar shroud. The IP40 front-face protection means it is rated against solid objects over 1 mm but not against water ingress — keep it inside a dry enclosure. The auxiliary trip accessory specified for this unit is order code 3VA9608-0BB11; if your BOM already includes that accessory, the fit is direct.

Frequently asked questions

Who supplies 3VA1220-4GF42-0BH0 and how is it quoted for volume purchases?

This part is sourced through independent industrial distribution channels and is quoted to order against an RFQ. Availability and current pricing are confirmed at quote time.

What is the breaking capacity of 3VA1220-4GF42-0BH0 at 415 V?

The breaking capacity is 75.6 kA at 415 V, which is the figure to use for most European 400 V-class distribution systems.

Does 3VA1220-4GF42-0BH0 include an undervoltage release?

Yes, it is fitted with an undervoltage release (UVR) as standard, plus 2 auxiliary switches and 1 trip alarm switch.

What compliance documentation does this brand provide for 3VA1220-4GF42-0BH0?

As a Siemens SENTRON product, it carries the standard CE, UL, and CSA certifications typical for this class of MCCB. RoHS and REACH declarations are available through the manufacturer's documentation portal.

MPN
3VA1220-4GF42-0BH0