Skip to main content
Siemens 3VA1220-5EF32-0BC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1220-5EF32-0BC0 SENTRON MCCB, 200 A, 3-Pole, 187

MPN3VA1220-5EF32-0BC0

Siemens SENTRON 3VA1220-5EF32-0BC0, 3-pole molded case circuit breaker, 200 A, TM240 thermal-magnetic release, line protection version, 187 kA at 240 V, 70 mm depth, 105 mm width, 158 mm height.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1220-5EF32-0BC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA12205EF320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1220-5EF32-0BC0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C200 A
Current at 45 °C200 A
Current at 50 °C200 A
Current at 55 °C194 A
Current at 60 °C188 A
Current at 65 °C182 A
Current at 70 °C176 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 500 V30 kA
Breaking capacity at 690 V17 kA
Power loss, max.44.5 W
3VA1220-5EF32-0BC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
3VA1220-5EF32-0BC0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1220-5EF32-0BC0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA1220-5EF32-0BC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1220-5EF32-0BC0 — Mechanical
ParameterValue
Height158 mm
Width105 mm
Depth70 mm
Height (in)6.22 in
Width (in)4.13 in
Depth (in)2.76 in

Product details

What the 200 A continuous rating and 187 kA interrupting capacity mean for your panel

The Siemens SENTRON 3VA1220-5EF32-0BC0 is a 3-pole molded case circuit breaker (MCCB) in line protection configuration, carrying a continuous current rating Iu of 200 A at 40 °C through 50 °C with no derating — it holds the full 200 A up to that ambient. Above 50 °C the rating steps down: 194 A at 55 °C, 188 A at 60 °C, 182 A at 65 °C, and 176 A at 70 °C, so a panel builder running the breaker in a warm enclosure needs to account for that thermal curve. The interrupting capacity is the headline number here: 187 kA at 240 V, 121 kA at 415 V, 75.6 kA at 440 V, 30 kA at 500 V, and 17 kA at 690 V — that means this breaker can safely clear a fault up to 187 kA on a 240 V service without upstream cascading, which is the kind of rating you spec for high-fault industrial mains or transformer secondaries where the available fault current is substantial. The TM240 thermal-magnetic release means the thermal element is fixed-trip at 200 A (the breaker's continuous rating) and the magnetic instantaneous pickup is set at 240 A — a narrow band that gives fast short-circuit response while still riding through motor inrush on moderate loads. Undervoltage release is included as standard, so the breaker can be tripped remotely by a control signal or safety circuit.

Panel integration — footprint and auxiliary contacts

It ships with 2 auxiliary switches (HQ type) pre-installed, so you have status feedback (open/closed/tripped) without ordering a separate accessory block.

Frequently asked questions

Where can I buy 3VA1220-5EF32-0BC0 and get current pricing?

This part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

What are the key interrupting ratings for 3VA1220-5EF32-0BC0?

187 kA at 240 V, 121 kA at 415 V, 75.6 kA at 440 V, 30 kA at 500 V, and 17 kA at 690 V — these are the maximum fault currents the breaker can safely interrupt at each voltage level.

What is the continuous current rating and how does it derate with temperature?

The continuous rating is 200 A from 40 °C to 50 °C, then derates to 194 A at 55 °C, 188 A at 60 °C, 182 A at 65 °C, and 176 A at 70 °C.

What are the physical dimensions of 3VA1220-5EF32-0BC0?

Width 105 mm, height 158 mm, depth 70 mm — a standard 3-pole MCCB footprint.

MPN
3VA1220-5EF32-0BC0