Siemens 3VA1220-5EF32-0KA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1220-5EF32-0KA0 SENTRON MCCB, 200 A, 3-Pole, 121

MPN3VA1220-5EF32-0KA0

Siemens SENTRON 3VA1220-5EF32-0KA0, molded case circuit breaker, 3-pole, 200 A rated current at 40 °C, breaking capacity 121 kA at 415 V, line protection, shunt trip release, depth 70 mm, width 105 mm, height 158 mm.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1220-5EF32-0KA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA12205EF320AA0
3VA1220-5EF32-0KA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C200 A
Current at 45 °C200 A
Current at 50 °C200 A
Current at 55 °C194 A
Current at 60 °C188 A
Current at 65 °C182 A
Current at 70 °C176 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 500 V30 kA
Breaking capacity at 690 V17 kA
Power loss, max.42 W
3VA1220-5EF32-0KA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1220-5EF32-0KA0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1220-5EF32-0KA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1220-5EF32-0KA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1220-5EF32-0KA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height158 mm
Width105 mm
Depth70 mm
Height (in)6.22 in
Width (in)4.13 in
Depth (in)2.76 in

Product details

What the 200 A rating means for panel fit

The Siemens SENTRON 3VA1220-5EF32-0KA0 is a 3-pole molded case circuit breaker (MCCB) rated 200 A continuous at 40 °C, carrying the full 200 A through 50 °C before derating begins — at 55 °C it holds 194 A, at 60 °C 188 A, at 65 °C 182 A, and at 70 °C 176 A. That derating curve matters for a panel that runs warm: the breaker does not force a larger frame just because ambient hits 50 °C. The 121 kA breaking capacity at 415 V (187 kA at 240 V, 75.6 kA at 440 V, 30 kA at 500 V, 17 kA at 690 V) means it can interrupt a fault of that magnitude without upstream coordination failure — sized for high-fault industrial distribution. The TM240 thermal-magnetic release provides inverse-time overload and instantaneous short-circuit protection, and the integrated shunt trip (STL) allows remote tripping for emergency-stop or supervisory control.

Line protection design and shunt trip

The shunt trip release (STL) operates on a separate control voltage, allowing the breaker to be opened by a remote pushbutton, PLC output, or safety relay.

Mounting dimensions and panel integration

The 3VA1220-5EF32-0KA0 measures 105 mm wide, 158 mm high, and 70 mm deep — a standard 3-pole MCCB footprint for SENTRON 3VA frames.

Frequently asked questions

Where can I buy 3VA1220-5EF32-0KA0 and how is it quoted?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock or lead-time figures are published here.

Will 3VA1220-5EF32-0KA0 drop into a panel specified around 3VA1110-5ED36-0AC0 without rewiring?

Both are 3-pole SENTRON 3VA molded case circuit breakers on the same frame footprint, so the 105 mm width and 70 mm depth are identical. The 3VA1220-5EF32-0KA0 carries a higher 200 A rating and higher breaking capacity (121 kA at 415 V) than the 3VA1110-5ED36-0AC0 — if the original panel's busbars and cable are sized for the lower rating, the breaker will mount but the upstream protection and conductor sizing must be verified for the higher current.

What compliance documentation does Siemens provide for 3VA1220-5EF32-0KA0?

The SENTRON 3VA series carries IEC 60947-2 certification for molded case circuit breakers. Siemens provides declarations of conformity for CE, UKCA, and EAC, plus UL/CSA listings for applicable variants. RoHS and REACH compliance declarations are available from Siemens documentation.

MPN
3VA1220-5EF32-0KA0