Skip to main content
Siemens 3VA1220-5GF42-0KA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1220-5GF42-0KA0 SENTRON MCCB, 200 A, 4-Pole, Shun

MPN3VA1220-5GF42-0KA0

Siemens SENTRON 3VA1220-5GF42-0KA0, molded case circuit breaker, 4-pole, 200 A, TM240 thermal-magnetic release, shunt trip (STL), line protection, 70 mm depth.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1220-5GF42-0KA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA12205GF420AA0
3VA1220-5GF42-0KA0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C200 A
Current at 45 °C200 A
Current at 50 °C200 A
Current at 55 °C194 A
Current at 60 °C188 A
Current at 65 °C182 A
Current at 70 °C176 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 500 V30 kA
Breaking capacity at 690 V17 kA
Power loss, max.42 W
3VA1220-5GF42-0KA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1220-5GF42-0KA0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1220-5GF42-0KA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1220-5GF42-0KA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1220-5GF42-0KA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height158 mm
Width140 mm
Depth70 mm
Height (in)6.22 in
Width (in)5.51 in
Depth (in)2.76 in

Product details

Siemens SENTRON 3VA1220-5GF42-0KA0 — 200 A MCCB with Shunt Trip

Interrupting capacity is 187 kA at 240 V AC, 121 kA at 415 V, 75.6 kA at 440 V, 30 kA at 500 V, and 17 kA at 690 V — covering most industrial fault-current scenarios without needing a current-limiting upstream device.

Thermal Derating and Ambient Performance

Above that, the TM240 release derates linearly: 194 A at 55 °C, 188 A at 60 °C, 182 A at 65 °C, and 176 A at 70 °C. For a panel running hot near the top of the enclosure, this derating curve tells you the actual continuous current the breaker will carry without nuisance tripping. The storage limits govern handling and warehousing, not running conditions.

Frequently asked questions

What is the interrupting capacity of 3VA1220-5GF42-0KA0 at 240 V?

The interrupting capacity is 187 kA at 240 V AC, with lower ratings at higher voltages: 121 kA at 415 V, 75.6 kA at 440 V, 30 kA at 500 V, and 17 kA at 690 V.

What is the depth of 3VA1220-5GF42-0KA0?

The depth is 70 mm (2.76 in), with a width of 140 mm (5.51 in) and height of 158 mm (6.22 in).

Where can I buy 3VA1220-5GF42-0KA0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
3VA1220-5GF42-0KA0