Skip to main content
Siemens 3VA1220-5MH32-0DA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1220-5MH32-0DA0 SENTRON MCCB, 200 A, 3-Pole, 187

MPN3VA1220-5MH32-0DA0

Siemens SENTRON 3VA1220-5MH32-0DA0, 3-pole molded case circuit breaker, 200 A rated continuous current, starter protection version with TM120M thermal-magnetic release, 187 kA breaking capacity at 240 V AC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1220-5MH32-0DA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionStarter protection
3VA1220-5MH32-0DA0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C200 A
Current at 45 °C200 A
Current at 50 °C200 A
Current at 55 °C192 A
Current at 60 °C188 A
Current at 65 °C184 A
Current at 70 °C180 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V30 kA
Breaking capacity at 690 V17 kA
3VA1220-5MH32-0DA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM120M
3VA1220-5MH32-0DA0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1220-5MH32-0DA0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1220-5MH32-0DA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1220-5MH32-0DA0 — Mechanical
ParameterValue
Height158 mm
Width105 mm
Depth70 mm

Product details

Breaking capacity is 187 kA at 240 V, 121 kA at 415 V, 30 kA at 440 V, and 17 kA at 690 V — the 240 V and 415 V figures cover the most common low-voltage distribution and motor branch-circuit fault levels, while the 690 V rating confirms suitability for 690 V line-to-line systems where available fault current stays under 17 kA.

Thermal performance and derating

Derating begins at 55 °C (192 A), dropping to 188 A at 60 °C, 184 A at 65 °C, and 180 A at 70 °C — the 70 °C figure matches the maximum operating ambient, so the derating curve covers the full temperature range a panel might see near a heat source or in a sealed enclosure.

Motor duty and endurance

Operating power at AC-3 duty (motor switching) at 400 V is 75 W — this is the power dissipated by the breaker under load, relevant for enclosure thermal calculations.

Physical footprint and mounting

Dimensions are 105 mm width, 158 mm height, and 70 mm depth.

The integrated auxiliary trip is specified as order code 3VA9608-0BB25 — that sub-assembly is the undervoltage release module that mates with this breaker. No auxiliary contact version is included as standard.

Frequently asked questions

What is the breaking capacity of 3VA1220-5MH32-0DA0 at 415 V?

The breaking capacity at 415 V is 121 kA, which covers the typical fault level in most low-voltage industrial distribution systems.

Where can I buy 3VA1220-5MH32-0DA0?

This part is sourced and quoted to order against an RFQ through independent distribution — submit a request for quote and we will confirm availability and current pricing at that time.

MPN
3VA1220-5MH32-0DA0