Skip to main content
Siemens 3VA1220-6EF32-0AJ0 — Molded Case Circuit Breakers (MCCB)

Siemens SENTRON 3VA1220-6EF32-0AJ0 MCCB, 200 A, 3-Pole, 220

MPN3VA1220-6EF32-0AJ0

Siemens SENTRON 3VA1220-6EF32-0AJ0, molded case circuit breaker, 3-pole, 200 A, 220 kA at 240 V, line protection with TM240 release.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1220-6EF32-0AJ0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AB11
3VA1220-6EF32-0AJ0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C200 A
Current at 45 °C200 A
Current at 50 °C200 A
Current at 55 °C194 A
Current at 60 °C188 A
Current at 65 °C182 A
Current at 70 °C176 A
Switching capacity classH
Breaking capacity at 240 V220 kA
Breaking capacity at 415 V154 kA
Breaking capacity at 440 V36 kA
Breaking capacity at 690 V17 kA
3VA1220-6EF32-0AJ0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
3VA1220-6EF32-0AJ0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1220-6EF32-0AJ0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA1220-6EF32-0AJ0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1220-6EF32-0AJ0 — Mechanical
ParameterValue
Height158 mm
Width105 mm
Depth70 mm

Product details

The Siemens SENTRON 3VA1220-6EF32-0AJ0 is a 3-pole molded case circuit breaker rated for 200 A continuous current at 40 °C, with a TM240 thermal-magnetic overcurrent release.

At 55 °C it derates to 194 A, at 60 °C to 188 A, at 65 °C to 182 A, and at 70 °C to 176 A. The interrupting ratings span four voltage levels: 220 kA at 240 V, 154 kA at 415 V, 36 kA at 440 V, and 17 kA at 690 V. That 220 kA figure covers the high-end utility fault duty common in North American 240 V delta services. At 690 V the 17 kA still clears most industrial motor-circuit faults, but verify against your transformer nameplate if you're feeding a 690 V drive bus. It's a straightforward line-protection device for feeder or main breaker duty where you don't need selective coordination curves. That gives you two NO/NC status signals for PLC or indication and a dedicated alarm contact that latches on a trip event — useful for remote fault annunciation without tying up the aux contacts.

MPN
3VA1220-6EF32-0AJ0