Siemens 3VA1220-6EF42-0AB0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1220-6EF42-0AB0 SENTRON MCCB, 200 A, 4-Pole, TM24

MPN3VA1220-6EF42-0AB0

Siemens SENTRON 3VA1220-6EF42-0AB0, molded case circuit breaker, 4-pole, TM240 overcurrent release, 200 A rated current at 40 °C, breaking capacity 220 kA at 240 V AC.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1220-6EF42-0AB0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA12206EF420AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA11

Ratings

3VA1220-6EF42-0AB0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C200 A
Current at 45 °C200 A
Current at 50 °C200 A
Current at 55 °C194 A
Current at 60 °C188 A
Current at 65 °C182 A
Current at 70 °C176 A
Switching capacity classH
Breaking capacity at 240 V220 kA
Breaking capacity at 415 V154 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 500 V30 kA
Breaking capacity at 690 V17 kA
Power loss, max.42 W

Protection & Trip Unit

3VA1220-6EF42-0AB0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA1220-6EF42-0AB0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1220-6EF42-0AB0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA1220-6EF42-0AB0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1220-6EF42-0AB0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height158 mm
Width140 mm
Depth70 mm
Height (in)6.22 in
Width (in)5.51 in
Depth (in)2.76 in

Product details

What this MCCB carries and where it fits

The Siemens 3VA1220-6EF42-0AB0 is a SENTRON molded case circuit breaker (MCCB) in a 4-pole configuration, designed for line protection in distribution panels and switchgear assemblies. Its TM240 thermal-magnetic release provides overload and short-circuit protection, with a rated current of 200 A at 40 °C that holds flat through 50 °C before derating to 176 A at 70 °C — useful when the breaker lands in a warm enclosure or next to other heat sources. Breaking capacity is the headline number here: 220 kA at 240 V AC, 154 kA at 415 V, 75.6 kA at 440 V, 30 kA at 500 V, and 17 kA at 690 V. That 220 kA figure at 240 V means this breaker can interrupt a massive fault without external current-limiting fuses — it's sized for high-available-fault-current panels, typically close to a transformer or in a main distribution board. Rated insulation voltage is 800 V, and max power loss sits at 42 W. The breaker ships with two auxiliary switches (HP type) integrated, so you get status feedback without adding external blocks. No undervoltage release, no ground-fault monitoring, no communication function — this is a straight line-protection MCCB, not a multifunction trip unit.

Thermal derating and panel integration

The 200 A rating holds from 40 °C to 50 °C, then drops to 194 A at 55 °C, 188 A at 60 °C, 182 A at 65 °C, and 176 A at 70 °C. If your panel ambient runs above 50 °C, size the upstream conductor and downstream load for the derated current, not the nameplate 200 A. The 42 W power loss at full load is moderate for a 200 A frame — ventilation or spacing from other breakers is still prudent. Mounting footprint: 158 mm tall, 140 mm wide, 70 mm deep. That 70 mm depth is shallow enough for most 600 mm deep enclosures, leaving room for rear-mounted busbars or cable ducts. The 4-pole width (140 mm) matches the standard SENTRON 3VA frame spacing — it will bolt directly onto a 4-pole busbar system without adapters. Operating temperature range is -25 °C to 70 °C; storage range is -40 °C to 80 °C. The storage minimum matters if this breaker sits in an unheated warehouse before installation — it can handle the cold, but let it warm above -25 °C before closing the contacts under load.

Lifecycle and sourcing posture

For BOM planning, the 3VA1220-6EF42-0AB0 is a standard catalog item in the SENTRON 3VA line. It is sourced and quoted to order against an RFQ through independent distribution; current pricing and availability are confirmed at quote time. No second-source cross-reference is required at this stage, but if you are evaluating alternatives, the 5SQ2670-2YA63 series occupies a similar 200 A 4-pole MCCB class — verify the mounting hole pattern and terminal layout before substituting.

Frequently asked questions

What is the breaking capacity of 3VA1220-6EF42-0AB0 at different voltages?

Breaking capacity is 220 kA at 240 V AC, 154 kA at 415 V, 75.6 kA at 440 V, 30 kA at 500 V, and 17 kA at 690 V. The 220 kA rating at 240 V is exceptionally high for a 200 A frame.

How does the 3VA1220-6EF42-0AB0 derate at elevated temperatures?

The 200 A rating holds from 40 °C through 50 °C, then derates to 194 A at 55 °C, 188 A at 60 °C, 182 A at 65 °C, and 176 A at 70 °C. The TM240 release is calibrated for the 40 °C baseline.

What are the mounting dimensions of 3VA1220-6EF42-0AB0?

Height 158 mm, width 140 mm, depth 70 mm. The 70 mm depth fits standard 600 mm deep enclosures with room for rear busbars.

Where can I buy 3VA1220-6EF42-0AB0 and get current pricing?

The part is sourced and quoted to order against an RFQ through independent distribution. Submit a request for quote; availability and current pricing are confirmed at quote time.