Skip to main content
Siemens 3VA1220-6EF42-0AD0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1220-6EF42-0AD0 SENTRON MCCB, 200 A, 4-Pole, TM24

MPN3VA1220-6EF42-0AD0

Siemens SENTRON 3VA1220-6EF42-0AD0, molded case circuit breaker, 4-pole, TM240 thermal-magnetic release, rated 200 A at 40 °C, breaking capacity 220 kA at 240 V AC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1220-6EF42-0AD0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA12206EF420AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1220-6EF42-0AD0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C200 A
Current at 45 °C200 A
Current at 50 °C200 A
Current at 55 °C194 A
Current at 60 °C188 A
Current at 65 °C182 A
Current at 70 °C176 A
Switching capacity classH
Breaking capacity at 240 V220 kA
Breaking capacity at 415 V154 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 500 V30 kA
Breaking capacity at 690 V17 kA
Power loss, max.42 W
3VA1220-6EF42-0AD0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1220-6EF42-0AD0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1220-6EF42-0AD0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA1220-6EF42-0AD0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1220-6EF42-0AD0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height158 mm
Width140 mm
Depth70 mm
Height (in)6.22 in
Width (in)5.51 in
Depth (in)2.76 in

Product details

It carries a TM240 thermal-magnetic release, rated 200 A continuously at 40 °C, and holds that same 200 A rating through 50 °C before derating to 194 A at 55 °C and 176 A at 70 °C. That thermal curve means this breaker handles full load in a warm panel without nuisance tripping — useful when the enclosure sits near process heat or in a non-climate-controlled electrical room.

Breaking capacity by voltage level

The interrupting ratings are given at five voltage points: 220 kA at 240 V, 154 kA at 415 V, 75.6 kA at 440 V, 30 kA at 500 V, and 17 kA at 690 V.

The breaker measures 140 mm wide by 158 mm high by 70 mm deep. The 4-pole width (140 mm) matches the common 4-module footprint for SENTRON 3VA breakers, so a panel laid out for a 3VA1110 frame accepts this one without re-drilling the mounting plate.

Auxiliary and internal configuration

The breaker ships with three auxiliary switches (HQ type) installed. If your application needs shunt trip or UVR, you add those as external accessories; the breaker body itself is a straight thermal-magnetic line-protection device with auxiliary contacts for status feedback.

Maximum power loss is 42 W — that's the heat to account for in the enclosure thermal calculation.

Frequently asked questions

What is the breaking capacity of 3VA1220-6EF42-0AD0 at 480 V?

The interrupting rating is 75.6 kA at 440 V and 30 kA at 500 V. At 480 V the value falls between those two points; for coordination studies use the 440 V figure (75.6 kA) as the conservative bound.

Will 3VA1220-6EF42-0AD0 drop into a panel designed for 3VA1110-5EF32-0AM0?

Both are 4-pole SENTRON 3VA breakers with the same 140 mm width and 158 mm height, so the mounting hole pattern and bus-bar spacing are identical. The 70 mm depth is also shared. The panel layout should accept this breaker without rewiring or re-drilling.

Where can I buy 3VA1220-6EF42-0AD0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

MPN
3VA1220-6EF42-0AD0