Siemens 3VA1220-6EF42-0CH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1220-6EF42-0CH0 SENTRON MCCB, 200 A, 4-Pole, 220

MPN3VA1220-6EF42-0CH0

Siemens SENTRON 3VA1220-6EF42-0CH0, molded case circuit breaker, 4-pole, 200 A rated current at 40 °C, 220 kA breaking capacity at 240 V, line protection design with undervoltage release and auxiliary switches.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1220-6EF42-0CH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA12206EF420AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12

Ratings

3VA1220-6EF42-0CH0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C200 A
Current at 45 °C200 A
Current at 50 °C200 A
Current at 55 °C194 A
Current at 60 °C188 A
Current at 65 °C182 A
Current at 70 °C176 A
Switching capacity classH
Breaking capacity at 240 V220 kA
Breaking capacity at 415 V154 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 500 V30 kA
Breaking capacity at 690 V17 kA
Power loss, max.44.5 W

Protection & Trip Unit

3VA1220-6EF42-0CH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA1220-6EF42-0CH0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1220-6EF42-0CH0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3

Environmental

3VA1220-6EF42-0CH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1220-6EF42-0CH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height158 mm
Width140 mm
Depth70 mm
Height (in)6.22 in
Width (in)5.51 in
Depth (in)2.76 in

Product details

MCCB for high-fault panels

The Siemens SENTRON 3VA1220-6EF42-0CH0 is a 4-pole molded case circuit breaker rated 200 A continuously at 40 °C, sized for main feeder or large subfeed protection in distribution panels. Its 220 kA interrupting capacity at 240 V handles high available fault current at the service entrance — common where utility transformers sit close to the switchboard. The 4-pole construction covers three-phase-plus-neutral, so it's the right choice for TN-S or TN-C-S systems where the neutral needs overcurrent protection. Breaking capacity steps down with voltage: 154 kA at 415 V, 75.6 kA at 440 V, 30 kA at 500 V, and 17 kA at 690 V. That SCCR curve means the same frame supports 480 V delta or 600 V wye installations, but the available fault current at the higher voltage must stay under the 30 kA or 17 kA ceiling respectively. For a 480 V panel with 65 kA available, this breaker fits only if the line side is impedance-limited or current-limited by an upstream device. Rated insulation voltage is 800 V, so the breaker is electrically rated for 690 V systems without derating the insulation path. The 44.5 W maximum power loss at full load matters for enclosure thermal rise — in a sealed NEMA 12 panel, that heat adds to the internal ambient and may require derating per the thermal curve above 40 °C.

Thermal derating and ambient range

The 3VA1220-6EF42-0CH0 holds full 200 A rating from 40 °C through 50 °C. Above that, current must be reduced: 194 A at 55 °C, 188 A at 60 °C, 182 A at 65 °C, and 176 A at 70 °C. In a hot switchroom or outdoor enclosure in direct sun, the 70 °C operating limit is the absolute ceiling — the breaker will still function but at 176 A continuous. Storage range is -40 °C to 80 °C, covering cold warehouse or hot container shipping without damage.

Built-in accessories and wiring

This variant ships with an undervoltage release (UVR) factory-installed — when control voltage drops, the breaker trips immediately, which is standard for emergency-stop or safety-shutdown circuits that need a loss-of-voltage trip. Auxiliary contacts include 2 auxiliary switches plus 1 trip alarm switch (HQ type), giving three separate signal paths for status feedback to a PLC or annunciator panel. The base switch mechanism is order code 3VA12206EF420AA0, meaning the trip unit, frame, and internal parts are a matched assembly — not a field-upgrade kit. Dimensions are 158 mm high, 140 mm wide, 70 mm deep. The 140 mm width is the standard 4-pole SENTRON 3VA12 frame footprint — it occupies four 35 mm DIN-rail modules (each 17.5 mm plus spacing). Panel cutout and busbar spacing must accommodate the 158 mm height; verify clearance above for arc-chamber venting per Siemens installation instructions.

Frequently asked questions

What are the key ratings for 3VA1220-6EF42-0CH0?

Rated 200 A continuous at 40 °C, 4-pole, with breaking capacity of 220 kA at 240 V, 154 kA at 415 V, 75.6 kA at 440 V, 30 kA at 500 V, and 17 kA at 690 V. Insulation voltage is 800 V.

How do I get pricing and availability for 3VA1220-6EF42-0CH0?

Submit an RFQ through this listing. The part is sourced through independent distribution; current pricing and lead time are confirmed at quote time.

What accessories come with this MCCB?

Factory-installed undervoltage release (UVR), 2 auxiliary switches plus 1 trip alarm switch (HQ type). The base switch mechanism is 3VA12206EF420AA0.

What are the physical dimensions of 3VA1220-6EF42-0CH0?

Height 158 mm, width 140 mm, depth 70 mm. The 140 mm width occupies four 35 mm DIN-rail modules.