Siemens 3VA1225-1AA32-0AB0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1225-1AA32-0AB0 SENTRON Switch Disconnector, 250

MPN3VA1225-1AA32-0AB0

Siemens SENTRON 3VA1 IEC frame switch disconnector, 3-pole, 250 A, busbar connection, IP40 front, 2 auxiliary switches HP.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VA1225-1AA32-0AB0 — Identification
ParameterValue
Product designationSwitch disconnector
Brand / rangeSENTRON
Product versionin MCCB design
3VA1225-1AA32-0AB0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C250 A
Current at 45 °C250 A
Current at 50 °C250 A
Current at 55 °C243 A
Current at 60 °C237 A
Current at 65 °C230 A
Current at 70 °C223 A
Power loss, max.57 W
3VA1225-1AA32-0AB0 — Construction & Connection
ParameterValue
Main circuit connection typebusbar connection
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1225-1AA32-0AB0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Motor drive optionYes
Auxiliary CO contacts2
3VA1225-1AA32-0AB0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1225-1AA32-0AB0 — Mechanical
ParameterValue
Height158 mm
Width105 mm
Depth70 mm

Product details

That means it's sized for a main isolation point on a 250 A bus, not for branch circuit protection. The frame is designed for busbar connection on the front terminals, so it bolts directly into a panel's vertical bus rather than wiring out to cable lugs.

The closest peer in the SENTRON family is the 3VA2225-5JQ32-0AK0, a molded case circuit breaker with the same 250 A rating but in a taller frame (181 mm vs 158 mm) and deeper (86 mm vs 70 mm). The breaker adds overcurrent protection (ETU560 trip unit) and communication, so it won't drop into the same footprint — the disconnect is shorter and lighter, built for isolation-only duty. If your panel spec calls for a disconnect, the 3VA1225-1AA32-0AB0 is the right fit; if you need protection, you're looking at the breaker variant.

Mounts on the panel front with IP40 protection on the front face — suitable for dry indoor enclosures, not washdown zones. The 70 mm depth leaves room behind the panel for busbar runs. Optional motor drive can be added for remote switching.

Mechanical service life is 15,000 switching cycles typical.

Frequently asked questions

Where can I buy 3VA1225-1AA32-0AB0?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

Will 3VA1225-1AA32-0AB0 drop into a panel specified for 3VA2225-5JQ32-0AK0?

No — the disconnect is shorter (158 mm vs 181 mm) and shallower (70 mm vs 86 mm) than the breaker variant, so it will not align with the same mounting holes or busbar connections without adapter hardware.

What is the rated current of this switch disconnector?

250 A continuous at 40 °C, derating to 223 A at 70 °C. No overload or short-circuit protection — it is a pure disconnect.

MPN
3VA1225-1AA32-0AB0