Skip to main content
Siemens 3VA1225-1AA32-0AD0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1225-1AA32-0AD0 SENTRON Switch Disconnector, 250

MPN3VA1225-1AA32-0AD0

Siemens SENTRON 3VA1225-1AA32-0AD0, switch disconnector, 3-pole, In=250 A, without overload or short-circuit protection, IP40 front, busbar connection, 3 auxiliary switches HQ.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1225-1AA32-0AD0 — Identification
ParameterValue
Product designationSwitch disconnector
Brand / rangeSENTRON
3VA1225-1AA32-0AD0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C250 A
Current at 45 °C250 A
Current at 50 °C250 A
Current at 55 °C243 A
Current at 60 °C237 A
Current at 65 °C230 A
Current at 70 °C223 A
Power loss, max.57 W
3VA1225-1AA32-0AD0 — Construction & Connection
ParameterValue
Main circuit connection typebusbar connection
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1225-1AA32-0AD0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Motor drive optionYes
Auxiliary CO contacts3
3VA1225-1AA32-0AD0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1225-1AA32-0AD0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.15 000
Height158 mm
Width105 mm
Depth70 mm

Product details

The Siemens 3VA1225-1AA32-0AD0 is a SENTRON switch disconnector in an MCCB-style housing — 3-pole, rated 250 A continuous, with no overload or short-circuit protection built in. That makes it a pure isolation and switching device for a circuit that's already protected upstream or by a separate breaker. It's meant for applications where you need a visible air gap and a load-break rated switch, not a full molded-case breaker. The 250 A rating holds flat from 40 °C through 50 °C, then derates to 243 A at 55 °C, 237 A at 60 °C, 230 A at 65 °C, and 223 A at 70 °C. The mechanical service life is 15,000 operating cycles, typical for this class of disconnect.

The main circuit connection is busbar, front terminal arrangement, so it's designed for busbar-stacked panels where you run the main feed horizontally and tap off vertically. No undervoltage release, no voltage trip, no communication module — it's a straightforward disconnect with aux contacts for remote position monitoring.

Frequently asked questions

What are the key ratings for 3VA1225-1AA32-0AD0?

It's a 3-pole switch disconnector rated 250 A continuous at 40–50 °C, with a thermal derating curve down to 223 A at 70 °C. Insulation voltage is 800 V, operating voltage is 690 V AC or 500 V DC. Mechanical service life is 15,000 cycles.

How does 3VA1225-1AA32-0AD0 compare to 3VA2225-5JQ32-0AK0?

The 3VA2225-5JQ32-0AK0 is a full molded-case circuit breaker with electronic overcurrent release (ETU560) and communication function, while the 3VA1225-1AA32-0AD0 is a switch disconnector with no overload or short-circuit protection. The breaker is deeper (86 mm vs. 70 mm) and taller (181 mm vs. 158 mm), so it won't drop into the same panel cutout without rework. If you need a disconnect only, the 3VA1225 is the right part; if you need integrated protection and communication, the 3VA2225 is the functional upgrade.

Where can I buy 3VA1225-1AA32-0AD0?

This part is sourced and quoted to order against an RFQ through independent distribution. Current pricing and availability are confirmed at quote time — submit an RFQ for a firm price and lead time.

MPN
3VA1225-1AA32-0AD0