Skip to main content
Siemens 3VA1225-1AA32-0BA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1225-1AA32-0BA0 SENTRON Switch Disconnector, 250

MPN3VA1225-1AA32-0BA0

Siemens SENTRON 3VA1225-1AA32-0BA0, switch disconnector, 3VA1 IEC frame 250, 3-pole, In=250 A, without overload protection, without short-circuit protection, with undervoltage release (UVR) 24 V DC, busbar connection, front terminal.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VA1225-1AA32-0BA0 — Identification
ParameterValue
Product designationSwitch disconnector
Brand / rangeSENTRON
Product versionin MCCB design
3VA1225-1AA32-0BA0 — Ratings
ParameterValue
Number of poles3
Power loss, max.57 W
3VA1225-1AA32-0BA0 — Construction & Connection
ParameterValue
Main circuit connection typebusbar connection
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1225-1AA32-0BA0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1225-1AA32-0BA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1225-1AA32-0BA0 — Mechanical
ParameterValue
Height158 mm
Width105 mm
Depth70 mm

Product details

The Siemens SENTRON 3VA1225-1AA32-0BA0 is a 3-pole switch disconnector in the 3VA1 IEC frame 250, rated for a continuous current Iu of 250 A. It is designed for load-break isolation, not for overload or short-circuit protection — the description explicitly states 'without overload protection w/o short-circuit protection'. There are no auxiliary contacts (0 CO contacts) and no communication function. The main circuit connects via busbar connection at the front terminals.

Rated continuous current Iu of 250 A is the maximum current the switch can carry continuously without exceeding its thermal limits. The 3-pole switch handles three-phase AC circuits up to 690 V AC 50/60 Hz, or DC circuits up to 500 V. Dimensions: 105 mm wide, 158 mm high, 70 mm deep. The width is the critical panel-space dimension — at 105 mm it takes up about 6 standard DIN-rail module widths (assuming 17.5 mm per module). The depth of 70 mm means it will fit most standard distribution boards, but check the door clearance if the panel has a shallow back box. This is a disconnect for isolation and infrequent load-break, not a contactor for cyclic duty. The wide storage range is useful for spares kept in unheated warehouses.

MPN
3VA1225-1AA32-0BA0