Skip to main content
Siemens 3VA1225-1AA32-0CA0 — Molded Case Circuit Breakers (MCCB)

Siemens SENTRON 3VA1225-1AA32-0CA0 Switch Disconnector, 250

MPN3VA1225-1AA32-0CA0

Siemens SENTRON 3VA1225-1AA32-0CA0, switch disconnector in MCCB design, IEC frame 250, 3-pole, In=250 A, without overload or short-circuit protection, with undervoltage release 120-127 V AC 50/60 Hz, busbar connection, IP40 front.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1225-1AA32-0CA0 — Identification
ParameterValue
Product designationSwitch disconnector
Brand / rangeSENTRON
Product versionin MCCB design
3VA1225-1AA32-0CA0 — Ratings
ParameterValue
Number of poles3
Power loss, max.57 W
3VA1225-1AA32-0CA0 — Construction & Connection
ParameterValue
Main circuit connection typebusbar connection
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1225-1AA32-0CA0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1225-1AA32-0CA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1225-1AA32-0CA0 — Mechanical
ParameterValue
Height158 mm
Width105 mm
Depth70 mm

Product details

The Siemens SENTRON 3VA1225-1AA32-0CA0 is a 3-pole switch disconnector in an MCCB-style housing, rated for 250 A continuous current (Iu) and designed for isolation and switching without overload or short-circuit protection — it's a pure disconnect, not a circuit breaker. Rated insulation voltage is 800 V, with maximum operational voltage 690 V AC and 500 V DC. The unit includes a factory-fitted undervoltage release (UVR) rated for 120–127 V AC 50/60 Hz, which automatically opens the disconnector when control voltage drops — typical for emergency-stop or safety circuits where loss of control power must isolate the load.

The 250 A rated continuous current (Iu) sets the maximum uninterrupted load it can carry without overheating — sized for main feeders or large motor branch circuits in distribution panels. Short-time withstand ratings of 3 kA at both 0.5 s and 1 s mean it can survive a fault current of that magnitude for those durations without damage, but it does not interrupt faults — upstream overcurrent protection must clear the fault. Maximum power loss of 57 W at rated current matters for thermal management inside an enclosed panel — factor this into ventilation or derating if multiple units are ganged.

Measures 105 mm wide, 158 mm high, and 70 mm deep — standard MCCB footprint for a 250 A frame, mounts via the front terminals with busbar connection for the main circuit. No auxiliary contacts are included (0 CO contacts), and no communication function is built in — it's a standalone disconnect; add external aux contacts or a motor drive (optional extension available) if remote status or remote switching is needed. Operating temperature range is -25 °C to +70 °C, storage from -40 °C to +80 °C — suitable for most indoor industrial environments without special climate control.

MPN
3VA1225-1AA32-0CA0