Siemens SENTRON 3VA1 IEC frame 250, 3-pole switch disconnector, In=250 A, busbar front terminal, undervoltage release 120-127 V AC 50/60 Hz, 2 auxiliary switches HQ + 1 trip alarm switch HQ, IP40 front.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3VA1225-1AA32-0CH0 — Identification
ParameterValue
Product designationSwitch disconnector
Brand / rangeSENTRON
Product versionin MCCB design
3VA1225-1AA32-0CH0 — Ratings
ParameterValue
Number of poles3
Power loss, max.57 W
3VA1225-1AA32-0CH0 — Construction & Connection
ParameterValue
Main circuit connection typebusbar connection
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1225-1AA32-0CH0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA1225-1AA32-0CH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1225-1AA32-0CH0 — Mechanical
ParameterValue
Height158 mm
Width105 mm
Depth70 mm

Product details

The Siemens 3VA1225-1AA32-0CH0 is a SENTRON 3VA1 IEC frame 250 switch disconnector rated for 250 A continuous current (Iu) across 3 poles, with no overload or short-circuit protection built in — it is a pure disconnect for isolation and switching duty. The front terminal accepts busbar connections, and the unit carries an undervoltage release (UVR) coil rated 120–127 V AC 50/60 Hz, plus 2 auxiliary switches and 1 trip alarm switch, all HQ type.

The 250 A rated continuous current (Iu) governs the load it can carry without overheating — sized for a feeder or large motor branch circuit where the disconnect only needs to make and break under load, not clear faults. The 3-pole configuration handles three-phase AC circuits up to 690 V AC (max rated operational voltage) or DC circuits up to 500 V DC. HQ denotes high-qualified contacts rated for low-level switching. The mechanical endurance of 15 000 cycles is typical for a disconnect of this frame size — expect it to outlast the panel's service life in normal switching duty.

The unit measures 70 mm deep by 105 mm wide by 158 mm tall — fits a standard MCCB cutout in a panel or enclosure. The UVR coil draws from a 120–127 V AC control transformer; verify the control circuit can supply the coil inrush without dropping below the dropout threshold. The auxiliary and alarm switches are wired separately for status feedback.

Frequently asked questions

Where can I buy 3VA1225-1AA32-0CH0?

This part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

What is the depth of 3VA1225-1AA32-0CH0?

The depth is 70 mm, with a width of 105 mm and height of 158 mm.

What auxiliary contacts does this switch disconnector include?

It includes 2 auxiliary switches HQ and 1 trip alarm switch HQ, providing 3 CO contacts total for status feedback.