Siemens 3VA1225-1AA32-0DH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1225-1AA32-0DH0 SENTRON Switch Disconnector, 250

MPN3VA1225-1AA32-0DH0

Siemens SENTRON 3VA1, switch disconnector, 3-pole, 250 A, SD100, IP40 front, undervoltage release 208-230 V AC, 2 aux switches + 1 trip alarm switch HQ, busbar front connection.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3VA1225-1AA32-0DH0 — Identification
ParameterValue
Product designationSwitch disconnector
Brand / rangeSENTRON
Product versionin MCCB design
3VA1225-1AA32-0DH0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C250 A
Current at 45 °C250 A
Current at 50 °C250 A
Current at 55 °C243 A
Current at 60 °C237 A
Current at 65 °C230 A
Current at 70 °C223 A
Power loss, max.57 W
3VA1225-1AA32-0DH0 — Construction & Connection
ParameterValue
Main circuit connection typebusbar connection
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1225-1AA32-0DH0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Motor drive optionYes
Auxiliary CO contacts3
3VA1225-1AA32-0DH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1225-1AA32-0DH0 — Mechanical
ParameterValue
Height158 mm
Width105 mm
Depth70 mm

Product details

The Siemens 3VA1225-1AA32-0DH0 is a SENTRON 3VA1 switch disconnector in MCCB design — 3-pole, rated 250 A continuous, with no overload or short-circuit protection built in. It's a load-break switch for isolation and switching duty, not a circuit breaker. The 250 A rating holds flat from 40 °C to 50 °C; above that it derates to 243 A at 55 °C, 237 A at 60 °C, 230 A at 65 °C, and 223 A at 70 °C, so if your enclosure runs hot, factor that curve into the continuous current budget. The UVR drops the switch on loss of control voltage, which is standard for safety isolation schemes where you want the load disconnected if the control supply fails. The auxiliary contacts let a PLC or panel indicator confirm the switch position without climbing into the enclosure. Connection is busbar front-terminal, so it's designed for panel-mounted busbar systems — common in distribution boards where the bus runs across the front of the devices.

Footprint is 105 mm wide × 158 mm high × 70 mm deep — standard 3-pole MCCB form factor for the 3VA1 frame. Busbar connection on the front terminals means the bus runs across the device faces, not the sides. Mechanical service life is 15,000 switching cycles typical. Power loss is 57 W maximum at rated current. If you're switching DC loads, that 500 V ceiling is the limit.

Frequently asked questions

What is 3VA1225-1AA32-0DH0's listed depth?

The depth is 70 mm. Combined width is 105 mm and height is 158 mm.

MPN