Siemens 3VA1225-1AA32-0JA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1225-1AA32-0JA0 Switch Disconnector, 250 A, 3-Pol

MPN3VA1225-1AA32-0JA0

Siemens SENTRON 3VA1225-1AA32-0JA0, switch disconnector in MCCB design, IEC frame 250, 3-pole, In=250 A, without overload or short-circuit protection, shunt trip (STL) 110-127V DC/AC 50/60Hz, busbar connection, front terminal, IP40 front.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1225-1AA32-0JA0 — Identification
ParameterValue
Product designationSwitch disconnector
Brand / rangeSENTRON
Product versionin MCCB design
3VA1225-1AA32-0JA0 — Ratings
ParameterValue
Number of poles3
Power loss, max.57 W
3VA1225-1AA32-0JA0 — Construction & Connection
ParameterValue
Main circuit connection typebusbar connection
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1225-1AA32-0JA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1225-1AA32-0JA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1225-1AA32-0JA0 — Mechanical
ParameterValue
Height158 mm
Width105 mm
Depth70 mm

Product details

Switch disconnector for isolation, not protection

The Siemens 3VA1225-1AA32-0JA0 is a SENTRON switch disconnector in MCCB design — rated 250 A continuous current (Iu) across 3 poles, with a shunt trip (STL) release for remote tripping on 110-127 V DC or AC 50/60 Hz. It carries no overload or short-circuit protection elements, so its role is load-break isolation and emergency switching under load, not circuit protection. The 250 A rating means it handles full-load current for a feeder or large motor branch circuit, but the upstream protective device (fuse or MCCB) must provide the fault interruption — this part is rated only 3 kA for 1 s and 0.5 s withstand, not a full breaking capacity.

Rated insulation voltage Ui of 800 V and max operational voltage 690 V AC / 500 V DC cover standard 400/480 V industrial panels and 500 V DC bus applications. The 70 mm depth, 105 mm width, and 158 mm height place it in the 3VA frame-250 footprint — wider than the 76.2 mm frame-160 siblings (like 3VA1110-5EE32-0JA0), so it will not drop into a panel cutout designed for the smaller frame without reworking the mounting or busbar connections. Busbar connection on the front terminals is standard for panelboard or switchboard integration; no lug terminals are supplied. The shunt trip (STL) release is the only auxiliary release fitted — no undervoltage release, no auxiliary contacts, no communication module. If you need remote undervoltage protection or status feedback, you must add those externally or choose a variant with the UVR option and auxiliary switch block.

Frequently asked questions

What is the difference between 3VA1225-1AA32-0JA0 and 3VA1110-5EE32-0JA0?

The 3VA1110-5EE32-0JA0 is a 100 A molded case circuit breaker with thermal-magnetic overcurrent protection (TM220) and a 160 A frame size, while the 3VA1225-1AA32-0JA0 is a 250 A switch disconnector with no overcurrent protection on a 250 A frame. They share the SENTRON family and shunt trip option, but the frame width differs: 76.2 mm for the 160 A frame versus 105 mm for the 250 A frame, so they are not mechanically interchangeable without panel rework.

Where can I buy 3VA1225-1AA32-0JA0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.