Siemens 3VA1225-1AA32-0JH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1225-1AA32-0JH0 SENTRON Switch Disconnector, 250

MPN3VA1225-1AA32-0JH0

Siemens SENTRON 3VA1 series switch disconnector, IEC frame 250, 3-pole, In=250 A, busbar connection, shunt trip (STL) 110-127 V DC/AC, 2 auxiliary switches + 1 trip alarm switch HQ.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1225-1AA32-0JH0 — Identification
ParameterValue
Product designationSwitch disconnector
Brand / rangeSENTRON
Product versionin MCCB design
3VA1225-1AA32-0JH0 — Ratings
ParameterValue
Number of poles3
Power loss, max.57 W
3VA1225-1AA32-0JH0 — Construction & Connection
ParameterValue
Main circuit connection typebusbar connection
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1225-1AA32-0JH0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA1225-1AA32-0JH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1225-1AA32-0JH0 — Mechanical
ParameterValue
Height158 mm
Width105 mm
Depth70 mm

Product details

The Siemens 3VA1225-1AA32-0JH0 is a SENTRON 3VA1 switch disconnector in an MCCB design — it provides visible isolation and load-break capability without overload or short-circuit protection. Rated continuous current Iu is 250 A, so it handles full-load current on a feeder or a large motor branch circuit where the upstream device provides the protection. The 3-pole unit is sized for 690 V AC 50/60 Hz or 500 V DC maximum operational voltage.

Rated short-time withstand current is 3 kA at both 1 s and 0.5 s intervals. That figure tells you the disconnector can hold closed through a fault of that magnitude long enough for an upstream breaker to clear — it's not a short-circuit making or breaking rating, but a withstand rating for coordination studies. In a selective coordination chain, this part sits downstream of a device that can interrupt a fault above 3 kA.

Built-in auxiliary and trip options

That means remote tripping and status feedback are wired in from the start — no field-add kit needed. The shunt trip lets a safety PLC or E-stop circuit open the disconnector remotely. Three CO contacts are available for auxiliary signaling.

Panel footprint and connection

Measures 105 mm wide, 158 mm high, 70 mm deep. Main circuit connection is busbar via front terminals — typical for panelboard or switchboard mounting where busbars run horizontally across the front. IP40 on the front face (finger-safe, not washdown).

MPN
3VA1225-1AA32-0JH0