Specifications

3VA1225-4EF32-0JC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1225-4EF32-0JC0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C250 A
Current at 45 °C250 A
Current at 50 °C250 A
Current at 55 °C243.3 A
Current at 60 °C236.5 A
Current at 65 °C229 A
Current at 70 °C223 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V25 kA
Breaking capacity at 690 V11.9 kA
3VA1225-4EF32-0JC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
3VA1225-4EF32-0JC0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1225-4EF32-0JC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA1225-4EF32-0JC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1225-4EF32-0JC0 — Mechanical
ParameterValue
Height158 mm
Width105 mm
Depth70 mm

Product details

The interrupting ratings climb to 121 kA at 240 V, 75.6 kA at 415 V, 25 kA at 440 V, and 11.9 kA at 690 V — those numbers tell you the fault-clearing capability at each voltage level, and the 415 V figure is the one most European 400 V distribution panels care about. It does not carry undervoltage release, phase failure detection, ground fault monitoring, or communication functions — it is a straightforward thermal-magnetic breaker with a voltage-trigger capability.

Thermal derating and endurance

Above that, it steps down: 243.3 A at 55 °C, 236.5 A at 60 °C, 229 A at 65 °C, and 223 A at 70 °C. If your panel runs hot (e.g., inside a non-ventilated enclosure near transformers), use the 55 °C or 60 °C figure for sizing; the breaker will still carry load but at a reduced limit.

The 3VA1225-4EF32-0JC0 measures 70 mm deep, 105 mm wide, and 158 mm tall. The 105 mm width is the standard 3-pole MCCB footprint for this SENTRON frame — it occupies three 35 mm DIN-rail modules (3 x 35 mm). Depth of 70 mm means it will clear most standard enclosure backplates and gland plates, but check the busbar or cable entry clearance if you are retrofitting into a shallow panel.

Frequently asked questions

How do I get current pricing and availability for 3VA1225-4EF32-0JC0?

Submit an RFQ against this order code; we source through independent distribution and can confirm current pricing and stock availability at the time of quotation.

What are the key interrupting ratings for 3VA1225-4EF32-0JC0?

It is rated 121 kA at 240 V, 75.6 kA at 415 V, 25 kA at 440 V, and 11.9 kA at 690 V — the 415 V figure is the one most relevant for 400 V distribution panels.

What is the continuous current rating and thermal derating for this MCCB?

Rated continuous current Iu is 250 A, holding flat from 40 °C to 50 °C ambient. Above that it derates: 243.3 A at 55 °C, 236.5 A at 60 °C, 229 A at 65 °C, and 223 A at 70 °C.

MPN
3VA1225-4EF32-0JC0