Siemens 3VA1225-5EE32-0AA0 SENTRON MCCB, 250 A, 3-Pole, TM22

MPN3VA1225-5EE32-0AA0

Siemens SENTRON 3VA1225-5EE32-0AA0, molded case circuit breaker, 3-pole, 250 A at 40 °C, TM220 release, interrupting rating 187 kA at 240 V, IP40 front.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA1225-5EE32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA1225-5EE32-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C250 A
Current at 45 °C250 A
Current at 50 °C250 A
Current at 55 °C243 A
Current at 60 °C237 A
Current at 65 °C230 A
Current at 70 °C223 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 500 V30 kA
Breaking capacity at 690 V17 kA
Power loss, max.57 W
3VA1225-5EE32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM220
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1225-5EE32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1225-5EE32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1225-5EE32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1225-5EE32-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height158 mm
Width105 mm
Depth70 mm
Height (in)6.22 in
Width (in)4.13 in
Depth (in)2.76 in

Product details

The Siemens SENTRON 3VA1225-5EE32-0AA0 is a 3-pole molded case circuit breaker (MCCB) rated for 250 A continuous at 40 °C, with a TM220 thermal-magnetic overcurrent release — the '22' indicating the magnetic trip is fixed at 220 A. It's designed for line protection in distribution panels where you need high fault interruption: 187 kA at 240 V, 121 kA at 415 V, and still 17 kA at 690 V.

Interrupting ratings and thermal derating

At 415 V it still clears 121 kA, which covers most industrial secondary distribution. The thermal curve is flat from 40 °C to 50 °C (full 250 A), then drops to 243 A at 55 °C, 237 A at 60 °C, 230 A at 65 °C, and 223 A at 70 °C. If this panel lives in a hot mezzanine, size the load for the derated value at your ambient.

Frequently asked questions

Where can I buy 3VA1225-5EE32-0AA0 and get a price?

This part is sourced through independent distribution. Submit an RFQ for current pricing and availability — confirmed at quote time.

Will 3VA1225-5EE32-0AA0 drop into a panel specified around 3VA1112-5EE32-0AA0?

The 3VA1225 and 3VA1112 share the same SENTRON 3VA platform and similar mounting footprint, but the 1225 is a larger frame rated for 250 A vs the 1112's lower rating. The bus connections and lug kit may differ — verify the lug kit before swapping.

What are the key interrupting ratings for this MCCB?

187 kA at 240 V, 121 kA at 415 V, 75.6 kA at 440 V, 30 kA at 500 V, and 17 kA at 690 V.